VESUVIO VESIN10 Manuel D'installation Et D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note: For your safe use in winter, it's strongly recommended to equip heating priority
function. For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Rated Residual
Action Current mA
Fuse
Power Cord(mm
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
Fuse
Breaker
VESIN10
11
30
A
11
2
3×2.5
2
3×0.5
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
VESIN13
VESIN17
13
16
30
30
13
16
3×2.5
3×2.5
3×0.5
3×0.5
- 10 -
For users
VESIN28
VESIN36T
25
12
30
30
25
12
3×6
5×2.5
3×0.5
3×0.5
10m, wire diameter must be

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vesin13Vesin17Vesin28Vesin36t

Table des Matières