position the skimmer in the sump
-
Suction pipe in safety overflow Pull up cover as far as possible.
-
feed water into the skimmer compartment (if applicable)
-
open the water level adjuster (picture 6) fully by turning it anti-clockwise
-
start the skimmer pump
-
Set the pump controller to the lowest level.
-
close the water level adjuster until fine bubbles are visible between the bayonet and
-
the bottom of the skimmer cup (picture 7)
initially keep the foam level in the skimmer cup low to avoid over skimming and
-
possible flooding of the cup.
wait a minimum of 48 hours before the final adjustment, only then adjust the
-
controller up and down.
The specified at the safety overflow pipe min and max. Values for the water level are
-
not to be considered in the start-up phase.
After the start-up phase, set the controller to
-
turn the water level adjuster in or out until the fine air bubbles start bursting
-
approximately half way up the cups riser tube
Set the water level between min. and max.
-
Position the suction pipe above the safety overflow pipe.
-
If the safety overflow pipe is not used, adjust the water level in the area of the upper
-
edge of the pipe, lower edge of the bayonet (picture. 8). The suction tube can be
removed.
for dry foam turn the water level adjuster anti-clockwise, for wet foam clockwise
-
Important: Never allow the pump to run dry.
-
When pressing the feed timer button on the controller, the pump will stop for 10 minutes
and will resume automatically.
Picture 6
Water level adjuster Skimmer cup
Starting the skimmer
Picture 7
- 11 -
level 8, optimal for most aquariums.
Picture 8
Ozonizer