Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Limiteur de remplissage
pour chimie industrie
INSTRUCTIONS DE MONTAGE ET MODE D'EMPLOI
FR
LDR Type NT
Siège social :
Z.I. Sud - Rue des Epinettes
CS 50152 TORCY
77208 MARNE LA VALLÉE CEDEX 1
FRANCE
EN
NL
S.A.S au capital de 315 000 €
N°SIREN 698 202 868 00023
NAF 4674B
N°TVA FR 25 698 202 868
Version 07/2020 (Remplace Version 08/2017)
- DN 50 NT
-
DN 80 NT
- DN 80 INOX
EN 13616
LDR Type INOX
Tél : +33(0)1 60 05 18 53
Fax : +33(0)1 60 17 58 39
info@selfclimat-morvan.com
www.selfclimat-morvan.com

Publicité

Table des Matières
loading

Sommaire des Matières pour SelfClimat DN 50 NT

  • Page 1 - DN 50 NT Limiteur de remplissage DN 80 NT pour chimie industrie - DN 80 INOX INSTRUCTIONS DE MONTAGE ET MODE D'EMPLOI EN 13616 LDR Type INOX LDR Type NT Siège social : S.A.S au capital de 315 000 €...
  • Page 2: Table Des Matières

    VEUILLEZ LIRE ET PRENDRE PLEINE CONNAISSANCE DE CE MANUEL AVANT UTILISATION. TABLE DES MATIÈRES Marquage Caractéristiques générales Description Liste non exhaustive des produits chimiques pouvant être utilisés avec les LDR DN 50 NT et DN 80 NT Instructions d’utilisation Consignes de sécurité Mise en service Fonctionnement Montage Installation du limiteur de remplissage Entretien et dépannage...
  • Page 3: Marquage

    I) MARQUAGE Les matériaux de type limiteur de remplissage Self Climat DN 50 NT, DN 80 NT et DN 80 INOX sont conformes à la directive 2014/34/UE. Le matériel utilisable dans les atmosphères explosibles du groupe IIB est construit conformément aux normes suivantes : NF EN 13616-1 : 2016 (norme harmonisée)
  • Page 4: Liste Non Exhaustive Des Produits Chimiques Pouvant Être Utilisés Avec Les Ldr Dn 50 Nt Et Dn 80 Nt

    2.2 / Liste non exhaustive des produits chimiques pouvant être utilisés avec les LDR DN 50 NT et DN 80 NT 1 - acétate d'isopropyle 26 - chlorure de benzol 51 - huile de lin ROB 108 76 - shell sol E 2 - acétate d'éthyle...
  • Page 5: Fonctionnement Détaillé

    Fonctionnement détaillé PRINCIPE DE FONCTIONNEMENT DU LDR Self Climat TYPE NT ET INOX 1) LIMITEUR DE REMPLISSAGE EN POSITION REPOS - Le flotteur est en position basse. - Le piston en position haute (ouverture totale). - Les lumières d’écoulement sont totalement dégagées. 2) PROCESSUS DE FERMETURE AVANT LE NIVEAU N1 - La montée progressive du niveau à...
  • Page 6: Montage

    IV) MONTAGE 4.1 / Installation du limiteur de remplissage IMPORTANT : Pendant le montage, protégez le limiteur contre les impuretés telles que le sable ! 1 : Il est recommandé de positionner le Limiteur dans l’axe longitudinal du réservoir. 2 : Monter le Limiteur de Remplissage sur la douille du tuyau sous le plateau de trou d’homme en plaçant le flotteur sous le testeur.
  • Page 7: Entretien Et Dépannage

    / Entretien et dépannage Les opérations pouvant être effectuées par l’utilisateur se limitent à l’installation et aux raccordements. Toute intervention de démontage, réparation ou modification sur le limiteur de remplissage annule systématiquement la garantie constructeur. Par conséquent, toute intervention ne peut être effectuée que par la société «Self Climat» après retour de l’appareil d’origine à...
  • Page 8 Perspective 2 Méthode de test +/- 180 Moyen vérification manuelle fonctionnement du limiteur. A l’aide de l’anneau, exercer progressivement une Piquage 1" traction sur le câble afin d’amener le flotteur en position haute. Faire redescendre lentement le flotteur à sa LDR Self Climat position de repos.
  • Page 9: Données Techniques

    VII) DONNÉES TECHNIQUES Côte Type DN 50 NT Type DN 80 NT Type DN 80 Inox A (mm) Ø 50/60 Ø 80/90 Ø 80/90 B (mm) C (mm) Construction Type DN 50 NT Type DN 80 NT Type DN 80 Inox Corps Aluminium anodisé...
  • Page 10: Normes Et Agréments

    A ce jour le Limiteur de remplissage est conforme aux normes suivantes : Description Canada Europe Pays - Bas LDR Type DN 50 NT UL2583 CAN/ULC-S661-10 (R2016) EN 13616-1 KIWA BRL-K636/03 LDR Type DN 80 NT...
  • Page 11 Overfill prevention device - DN 50 NT DN 80 NT for chemical industry - DN 80 INOX FITTING AND OPERATING INSTRUCTIONS EN 13616 OPD Type INOX OPD Type NT S.A.S with capital of €315 000 Head office : Tel : +33(0)1 60 05 18 53 Z.I.
  • Page 12 PLEASE READ AND DIGEST THIS MANUAL BEFORE USING THE APPLIANCE. CONTENTS Marking General specifications Description Non-exhaustive list of chemicals that can be used with DN 50 NT and DN 80 NT overfill prevention devices Operating instructions Safety instructions Starting up Operation Fitting...
  • Page 13: Marking

    I) MARKING Self Climat DN 50 NT, DN 80 NT and DN 80 Inox type overfill prevention devices all conform to the Directive 2014/34/EU. This equipment, suitable for use in group IIB explosive atmospheres, is constructed according to the following European standards :...
  • Page 14: Non-Exhaustive List Of Chemicals That Can Be Used With Dn 50 Nt And Dn 80 Nt Overfill Prevention Devices

    2.2 / Non-exhaustive list of chemicals that can be used with DN 50 NT and DN 80 NT overfill prevention devices 1 - A1 oil 26 - dust-laying oil 51 - lamp oil 76 - propanol 2 - acetic acid...
  • Page 15: Detailed Operation

    Detailed operation OPERATING PRINCIPLE OF THE SELF CLIMAT NT AND STAINLESS STEEL OVERFILL PREVENTION DEVICES 1) OVERFILL PREVENTION DEVICE IN THE REST POSITION - The float is in the bottom position. - The piston is in the top position (fully open). - The drain ports are completely open.
  • Page 16: Fitting

    IV) FITTING 4.1 / Installation of the overfill prevention device IMPORTANT: Protect the overfill prevention device against impurities such as sand during fitting! 1 : We recommend positioning the overfill prevention device on the longitudinal axis of the tank. 2 : Mount the overfill prevention device on the pipe sleeve under the manhole plate placing the float under the tester.
  • Page 17: Maintenance And Troubleshooting

    4.2 / Maintenance and trouble shooting The operations that can be done by user are limited to installation and connecting up. Any dismantling, repair or modification to the overfill prevention device automatically cancels the manufacturer’s warranty. Consequently, this work can only be done by the «Self Climat» company after return of the appliance to the factory.
  • Page 18 Perspective 2 Test method +/- 180 A means of manually testing the correct operation of the float valve. Pull the cable progressively, using the ring, to bring the float to its top position. 1"Tapping Lower the float slowly to its rest position. Repeat this operation several times to make sure that nothing prevents the float moving freely throughout its travel.
  • Page 19: Technical Data

    VII) TECHNICAL DATA Dimension DN 50 NT Type DN 80 NT Type DN 80 Inox Type A (mm) Ø 50/60 Ø 80/90 Ø 80/90 B (mm) C (mm) Construction DN 50 NT Type DN 80 NT Type DN 80 Inox Type...
  • Page 20: Standards And Approvals

    To date the overfill prevention device conforms to the following standards: Description Canada Europe The Netherlands DN 50 NT OPD Type UL2583 CAN/ULC-S661-10 (R2016) EN 13616-1 KIWA BRL-K636/03 DN 80 NT OPD Type...
  • Page 21: Montage - En Gebruiksinstructies

    Overvulbeveiliging voor - DN 50 NT DN 80 NT de industrie en chemie - DN 80 INOX MONTAGE - EN GEBRUIKSINSTRUCTIES EN 13616 Overvulbeveiliging Type INOX Overvulbeveiliging Type NT Hoofdkantoor : S.A.S met een kapitaal van 315 000 € Tel : +33(0)1 60 05 18 53 Z.I.
  • Page 22 GELIEVE VOOR GEBRUIKT DEZE HANDLEIDING VOLLEDIG TE LEZEN. INHOUDSOPGAVE Markering Algemene kenmerken Omschijving Niet-volledige lijst van chemische producten die gebruikt kunnen Worden met de overvulbeveiligingen DN 50 NT en DN 80 NT Gebruiksinstructies Veiligheidsrichtlijnen Inbedrijfstelling Werking Installatie Installatie van de overvulbeveiliging...
  • Page 23: Markering

    I) MARKERING Apparatuur zoals de Self Climat overvulbeveiliging DN 50 NT, DN 80 NT en DN 80 INOX is in overeenstemming met richtlijn 2014/34/EU. materieel voor gebruik in groep IIB plaatsen waar ontploffingsgevaar kan heersen uit, is vervaardigd in overeenstemming met de volgende Europese normen :...
  • Page 24: Niet-Volledige Lijst Van Chemische Producten Die Gebruikt Kunnen Worden Met De Overvulbeveiligingen Dn 50 Nt En Dn 80 Nt

    2.2 / Niet-volledige lijst van chemische producten die gebruikt kunnen worden met de overvulbeveiligingen DN 50 NT en DN 80 NT 47 - stofwerende olie 70 - geurloze petroleum 24 - donkercarbonyl 1 - isopropylacetaat 48 - heldere AD oile...
  • Page 25 Gedetailleerde werking WERKINGPRINCIPE VAN DE SELF CLIMAT OVERVULBEVEILIGING TYPE NT EN INOX 1) OVERVULBEVEILIGING IN RUSTSTAND - De vlotter bevindt zich in lage positie. - De zuiger in hoge positie (volledig geopend). - De doorstroomopeningen zijn volledig vrij. 2) AFSLUITPROCEDURE VOOR NIVEAU L1 De toename van het niveau in het reservoir doet de vlotter stijgen.
  • Page 26: Installatie

    IV) INSTALLATIE 4.1 / Installatie van de overvulbeveiliging BELANGRIJK: Bescherm overvulbeveiliging tijdens de installatie tegen vuil, zoals zand! 1 : Het is raadzaam de beveiliging evenwijdig met de lengteas van het reservoir te plaatsen. Monteer de overvulbeveiliging in de leiding onder de het mangatdeksel, zodanig dat de vlotter zich onder de tester bevind.
  • Page 27: Onderhoud En Reparatie

    4.2 / Onderhoud en reparatie Handelingen die door de gebruiker uitgevoerd mogen worden, beperken zich tot de installatie en aansluiting. Bij ontmanteling, reparatie of wijziging van de overvulbeveiliging vervalt de fabrieksgarantie. Ontmateling, reparatie of wijziging van de overvulbeveiliging moeten uitgevoerd worden door «Self Climat» na h e t retour zenden van de overvulbeveiliging naar de fabriek.
  • Page 28 Aanzicht 2 Testmethode +/- 180 Middel voor de handmati e controle van de goede werking van de overvulbeveiliging. Met behulp van de ring aan de kabel trekken, 1"Tappin om de vlotter omhoog te brengen. De vlotter langzaam tot in zijn ruststand laten terugzakken.
  • Page 29: Technische Gegevens

    VII) TECHNISCHE GEGEVENS Merk DN 50 NT Type DN 80 NT Type DN 80 Inox Type A (mm) Ø 50/60 Ø 80/90 Ø 80/90 B (mm) C (mm) Constructie DN 50 NT Type DN 80 NT Type DN 80 Inox Type...
  • Page 30: Normen En Goedkeuringen

    Op dit moment is de overvulbeveiliging in overeenstemming met de volgende normen: Omschrijving Canada Europa Nederland Type DN 50 NT UL2583 CAN/ULC-S661-10 (R2016) EN 13616-1 KIWA BRL-K636/03 Type DN 80 NT UL2583 CAN/ULC-S661-10 (R2016) EN 13616-1 KIWA BRL-K636/03...

Ce manuel est également adapté pour:

Dn 80 ntDn 80 inox

Table des Matières