Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice – even if the appliance is still under
guarantee!
Fault
The light does not
work.
Floor of
the refrigerator
compartment is wet.
The temperature in
the refrigerator
compartment is too
cold.
The refrigerating unit
is switching on more
frequently and for
longer.
Possible cause
The bulb is defective.
Light switch is
jammed.
The condensation
channels or drainage
hole are blocked.
Temperature controller
has been set too high.
Appliance opened
frequently.
The ventilation
openings have been
covered.
Remedial action
Replace bulb. Fig. 7/B
1. Switch the appliance off.
2. Pull out mains plug or switch off
fuse.
3. Slide cover forwards and remove.
4. Change the bulb.
(Replacement bulb: 220–
240 V a.c., E14 bulb holder, see
defective bulb for wattage.)
Check whether it can be moved.
Fig. 7/A
Clean the condensation channels
and the drainage hole. See chapter
Cleaning the appliance. Fig. 6
Set temperature controller lower.
Do not open the appliance
unnecessarily.
Remove obstacles.