Hearth
The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not
independently supported.
The WESTFIRE WF32/UNIQ32 INSET wood inset stove has been tested and is suitable to be installed above a 12 mm
non combustible plate such as Westfire 12 mm glass plates or 20 mm slate plates. Installation of the stove must be
at a minimum height of 450 mm for 12 mm hearth. Installation of all hearths should comply in size and construction
so that it is in accordance with the provisions of the current Building Regulations Approved Document J.
The clearance distances to combustible material beneath, surrounding or upon the hearth and walls adjacent to
the hearth should comply with the guidance on the separation of combustible material given in Building Regula-
tions Approved Document J and also in these stove instructions.
If the stove is to be installed in front of a wooden floor, it must be covered with a non-combustible material at
least 12 mm thick, in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front
of the stove and 15 cm to each side measuring from the door of the combustion chamber.
Combustion air supply
In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in
which the stove is installed to provide combustion air. This is particularly necessary if the room is double-glazed
or a flue draught stabiliser is operating in the same room as the appliance. The provision of air supply to the
stove must be in accordance with current Building Regulations Approved Document J. An opening window is not
appropriate for this purpose. Air inlets must be positioned in such a way that they cannot be blocked. An air inlet
may be a vent (the vent must be open and the capacity of the vent sufficient when the stove is lit) or a fresh air
system linked to the stove.
The WESTFIRE WF32/UNIQ 32 INSET has an option of a closed air supply collar; this enables the stove to take all
combustion air (primary, secondary and tertiary) directly from outside with a 100 mm pipe from the stove.
Distance from rear to centre of top flue exit
Distance from floor to centre of rear flue exit
Distance from bottom of appliance casing to centre of Air intake
Westfire Insulated chambers
The WESTFIRE WF32/UNIQ32 stove is lined with heat deflection panels and baffles, these panels are designed
to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles
should not be removed other than for cleaning the stove. Any defective panels should be replaced.
Commissioning and handover
Ensure all parts (fire brick sets, grates) are fitted in accordance with the instructions given in the instruction
booklet.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, a
small fire may be lit to check that smoke and fumes are taken from the stove up the chimney and emitted safely
into the atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and notify them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to
use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons.
WESTFIRE · WF32
FLUE AND AIR INTAKE POSITIONS
13
WF32/UNIQ32
INSET
167 mm
405 mm
70 mm