UK
of the outlet socket of the stove. Registered smoke exempt models burning wood only can be installed on flue of
125mm throughout. Any bend in the chimney or connecting flue pipe should not exceed 45°. 90-degree bends
should not be used other than within 150 mm of stove rear flue outlet.
A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the
chimney should be satisfactory. Alternatively, the calculation procedure given in BS5854:1980 may be used as the
basis for deciding whether a particular chimney design will provide sufficient draught.
If it is found that there is excessive draught in the chimney, then either an adjustable flue damper or alternately a
draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in
its closed position leave a minimum continuous opening free area of at least 20 % of the total cross-sectional area
of the flue or flue pipe. Adequate provision e.g. easily accessible soot door or doors must be provided for sweep-
ing the chimney and connecting flue pipe.
Your appliance needs to be maintained routinely, the throat plate/baffle should be cleaned regularly (monthly).
The flue pipe can be cleaned using a flexible brush. Only Use a dry cloth on external surfaces. Over time the glass
may become dirty, clean with a damp cloth and polish off with damp cloth. If the stove has not been used for
some time the flue should be checked for blockages before use. Do not modify the appliance; only use spares
authorised by the manufacturer.
WF32 / UNIQ32
BUILDERS APERTURE SIZE
HOW TO REMOVE A WESTFIRE 32 DOOR
810 mm
WESTFIRE · WF32
WF UNIQ 32 BUILDERS DIMENSIONS
WF UNIQ 32
NARROW FRAME
WIDE FRAME
1) Remove safety plate
using allen key
2) Lift door until door
become released from
bottom point
3) Tilt door and lower until
door pin is released from
top location point
10
DEPTH
width
435 mm
820 mm
415 mm
820 mm