GB - INSTRUCTION MANUAL
Troubleshooting:
Compressor engine does not work
Cause:
No power present.
Solution: Check cables, plugs, fuses and outlets.
Cause:
Power level too low.
Solution: Avoid using long extension cords. If you have to use extension cords, make sure they are
sufficently thick (at least 2.5 mm
Cause:
Ambient temperature too low.
Solution: Do not operate below 5 °C.
Cause:
Engine overheating.
Solution: Let the engine cool down. Do not operate above 40°C ambient temperature.
Compressor engine working, but no pressure
Cause:
Seals leaky.
Solution: Check seals and let a certified technician replace them.
Cause:
Drain valve leaky.
Solution: Tighten the screw by hand. Check the seal on the valve and replace it if necessary.
Compressor engine working, gauge display pressure, tools not operating
Cause:
Hose connections leaky.
Solution: Check hoses and tools and replace if necessary.
Cause:
Working pressure valve leaky.
Solution: Check valve and replace if necessary.
Cause:
Pressure regulator set too low.
Solution: Increase pressure with the pressure regulator or use the tank pressure valve.
ERBA GmbH
A-1230 Wien
Talpagasse 6
Servicehotline: Tel: +43(0) 1 930 10 - 160 · Fax: +43(0) 1 930 10 - 960 · E-Mail: service@erba.at
).