Wavetek Meterman FG2C Manuel D'utilisation page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.Sweep Operation
Sweep/Manual
Sweep/Rate
Sweep/Time
Sweep/Mode
10.Amplitude Modulation
Depth
MODulation Frequency
Carrier BW
EXT Sensitivity
11.Frequency Modulation
Deviation
Modulation Frequency
EXT Sensitivity
12.Frequency Counter
Int./Ext.
Range
Accuracy
Time base
Resolution
Input Impedance
Sensitivity
13.General
LED Display
Power Source
Operation Environment
Storage Temperature & Humidity -10 °C to 70°C @ 70% R.H.(maximum).
Accessories
Dimension
Weight
Safety:
EMC: This product complies with requirements of the following European Community Directives: 89/336/EEC
(Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking). However,
electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement
circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement
circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the
presence of electronic interference.
FG2C
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
115, 230VAC ±15%, 50/60Hz
Indoor use, Altitude up to 2000m. Ambient Temperature 0°C to 40°C
Relative Humidity 80%(maximum). EN61010-1, Installation category II, Pollution Degree 2
1 each RTL-1, Instruction Manual,
Spare Fuse
243(w) x 93(H) x 292(D) mm
Approx. 2.0 kgs.
Meets EN61010-1:1993. Installation category II Pollution degree 2
FG3C
Switch selector
100:1 ratio max. and adjustable
0.5 Sec to 30 Sec adjustable
Lin./Log. switch selector
0 to 100%
400 Hz(INT), DC to 1 MHz (EXT)
100 Hz to 3 MHz (-3dB)
≤10Vpp for 100 % modulation
0 to ±5%
400Hz (INT), DC to 20 kHz (EXT)
≤10Vpp for 10% modulation
Switch selector
0.3 Hz to 3 MHz (5 Hz to 150 MHz EXT)
Time base accuracy ±1count
±20ppm (23°C ±5°C) after 30 minutes warm up
The maximum resolution is 10 nHz for 1Hz
and 1 kHz for 100MHz
1MΩ/150pf
≤ 35mVrms (5Hz to 100MHz)
≤ 45m Vrms (100MHz to150MHz)
6 digits; 7.6mm (.3 in) high
115, 230VAC ±15%, 50/60Hz
2 each RTL-1, Instruction Manual,
Spare Fuse
Approx. 2.2 kgs.
- 10 -