WIRING

WARNING
- Do not invert the neutral with the phase.
- Make the connection to an effi cient earthing system.
- The electrical power line to the burner must be fi tted with an omnipolar switch with an ope-
ning of at least 3 mm between the contacts.
- The earth connection to the terminal board of the burner must be made with a cable at least
20 mm longer than the phase and neutral cables.
- Must be workmanlike performed and comply with the regulations in force.
NOTE: Always make sure that no more than two wires are connected to each terminal.
1
2
M
MS
Key
CO
Hour-meter (possible)
F
Fuse
FR
Photoresistance
IG
Main switch
Ima
On/Off Switch
LI
On/Off switch lamp
LS
Lock-out warning light
(possible)
UK
MA
Control box terminal
board
28
2 2 3 4 5 6 7 8 9 10 11 12 31 32
VE1
TR
MB
8 7
6 5
4 3 2 1 N
MB
MS
PB
SC
TA-TC Boiler environment
TMF
TR
FR
VE2
PB
LI
Ima
Burner motor
Servomotor terminal
board
Burner connector
Plug
thermostat
2° Flame Modulation
Thermostat (optional)
Ignition transformer
MA
3
2
1
F
TS
L1
N
T1
TC-TA
T2
S3
H
B4
Z
CO
SC
TS
Safety thermostat
VE1
1st stage solenoid valve
VE2
2nd stage solenoid valve
Tmf
IG
L
N
LS
N
N

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sun g 2 pro

Table des Matières