Pv Array Requirements; Wire And Cable Size - Furrion net-zero MPPT 25A Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
8. Press the BATTERY SELECTION button to
select the correct battery type. (Figure 11)
9. Verify that system is operational, e.g. the
charge LED is blinking or sold green light.
(Figure 11)
Fig. 11

PV Array Requirements

The acceptable PV array size as below:
FSCC30PW-BL
Model
Maximum PV
300W
Power
Maximum PV
70V
open circuit
voltage (Voc)

Wire and Cable Size

The wiring and installation methods must
conform to all national and local electrical
code requirements, and need to follow RVIA
regulations.
11
PV Wire Size
Since the PV outputs can vary due to the
array connection method, the minimum
wire size must be in accordance with the
maximum array short-circuit current. The PV
array is suggested to be connected in series.
Please use PV Photovoltaic wire, the
reference size as below:
NOTE: The PV wire size listed is only for
reference. If there is a long distance between
the PV array and the controller, larger wires
can be used to reduce the voltage drop and
improve performance.
Battery Cable Size
The battery cable size must conform to the
rated current, the reference size as below:
FSCC60PW-BL
600W
135V
NOTE: The battery cable size is only for
reference. If there is a long distance between
the controller and the battery, larger cables
can be used to reduce the voltage drop and
improve performance.
PV short
Wire Gauge
circuit current
10A
12AWG
FSCC30PW-BL FSCC60PW-BL
Model
Maximum
25A
charge
current
10AWG
Cable Gauge
Maximum
15FT
Cable Length
Maximum
Wire Length
30FT
50A
6AWG
15FT

Publicité

Table des Matières