Installation and connection
• The transformer must be disconnected from the power supply during installation. It is not
sufficient to just turn off at the light switch!
Turn off the power when removing the corresponding electric circuit fuse or the switch of the
circuit breaker. Secure it against an unauthorised re-start, e.g. with a danger sign.
• Check that the mains cable is free of current e.g. with an appropriate tester.
• The electronic transformer can be mounted via two lateral openings.
Do not damage the dedicated transformer when mounting!
Pay attention when tightening the screws that no power, gas or water pipes can be
damaged! The same applies when drilling holes for dowels before mounting.
Depending on the mounting site, the dedicated transformer may be mounted in the space
between a concrete ceiling and the wood ceiling, for example. The electronic transformer must
not be embedded in insulating material since it could overheat; maintain a clearance of at least
20 cm around the transformer.
The maximum ambient temperature permitted for the electronic transformer is
+50 °C, you should therefore keep sufficient clearance from other appliances or
heating/water pipes.
You should not mount the electronic transformer in the direct vicinity of other electric/
electronic devices; keep a clearance of at least 20 cm.
• Open the two covers on the left and right of the electronic transformer; for this unscrew the
two screws respectively.
• Connect the mains cable to the corresponding terminal clamps (observe inscription on the
transformer!) on the primary side (label "PRI").
The maximum connection power at the mains voltage output must not exceed 500 W
otherwise the electronic transformer will be damaged (Overload of the conducting
paths on the board), loss of warranty!
• After installation the illuminants are to be connected to the electronic transformer.
According to the model of the transformer you bought there are one, two or three
connection terminal pairs.
Any number of illuminants can be operated via appropriate cables and distributor
clamps as long as the maximum connection power of the transformer is not
exceeded.
The connection line between transformer and illuminant must only be 2 m long each
at the maximum.
• Replace the two initially removed covers and screw them down with two screws each.
Observe that the different covers only fit on one specific side each.
These covers simultaneously relieve the strain from the mains cables or low voltage cables.
To operate the halogen transformer without covers is inadmissible!
Make sure to place the cables clearly into the strain reliefs!
• Verify that the correct output voltage has been set. Then turn on the mains voltage and the
illuminants connected to the transformer will light up (if necessary, activate the light switch).
Technical data
Item no.
1668380
Type
Mini
Output power
10-60W
Housing temperature
max. 75°C
Dimensions (W x H x L)
41 x 22 x 85 mm
Weight
ca. 65.5 g
Operating voltage ......................... 230 V~/50 Hz
Output voltage ..............................11.5 V~ eff.
Ambient temperature (ta) ..............max. +50 °C
For further technical details see the labels on the housing of the electronic
transformer!
Handling
• Only use in dry indoor locations. The product must not get damp or wet.
• Never look directly into the lit-up illuminant, this can lead to eye damage!
• Avoid the following unfavourable environmental conditions at the installation location and
during transportation:
- Damp or excess air humidity
- Direct sunlight
- Extreme cold or heat
- Dust or flammable gases, fumes or solvents
- Strong vibrations
- Strong magnetic fields such as those found in the vicinity of machinery or loudspeakers
• Ensure that the insulation for the entire product is neither damaged nor destroyed. The
housing may not be opened (only for mounting and connecting as described in this user's
manual)! The housing does not contain any serviceable parts.
• Check the product for damage before each use!
Care and cleaning
• The product is maintenance-free for you, you should never take it apart (except for mounting/
connecting as described in these operating instructions).
• Repair or maintenance work must be carried out by a specialist.
Disposal
1668266
1668264
Standard
Standard
10-60W
20-105W
max. 70°C
max. 80°C
39 x 30 x 168 mm
39 x 30 x 168 mm
ca. 101.5 g
ca. 114 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in
part, is prohibited. This publication represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.
Observe all the safety and mounting instructions contained in these operating
instructions.
If you detect any damage, do NOT connect the device to the mains voltage! Do not
turn it on at all in this case; it is no longer usable! There is a risk of a life-threatening
electric shock!
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
1668265
Standard
50-150W
max. 85°C
39 x 30 x 168 mm
ca. 159.6 g
1668263
Standard
50-210W
max. 75°C
43 x 39 x 199 mm
ca. 223.5 g
*1668263_4_5_6_380_V1_0918_02_mxs_m_en