Franke FPL 606 Mode D'emploi Et Installation page 18

Masquer les pouces Voir aussi pour FPL 606:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

• Adjust the two screws Vr of brackets 11a, by just placing them
in position.
• Hook the hood body to the two brackets 11a.
• Pull the Comfort Panel to open it, remove the filters one by
one, push them towards the rear part of the unit and pull
downwards at the same time .
• From inside the hood body, tighten the screws Vr to level the
body.
AIR OUTLET IN SUCTION VERSION
To fit the hood in suction version, connect the hood to the outlet
by means of a 150 o 120 mm ø rigid or flexible pipe, the choice
of which is left to the technician. The pipe can be fitted either at
the top or at the back of the hood.
Before proceeding with the connections, and in case they have
not been removed yet, remove the inclinable grid 8 and pvc pipe
7. The reduction flange 9 should only be removed to carry out
150 ø connections.
REAR OUTLET
• Please bear in mind that the exhaust opening must be carried
out following the drawing indicated in the wall boring para-
graph.
• Break the rear outlet using pliers.
• When using a 120 mm ø pipe, insert the reduction flange 9 in
the hood body outlet.
• Keep the pipe in position using clamps. The necessary material
is not supplied.
• Remove any charcoal anti-odour filters, if used.
TOP OUTLET
• Remove the inclinable grid 8.
• When using a 150 mm ø pipe, break the top air outlet along
the pre-cut line with pliers.
• When using a 120 mm ø pipe, insert the reduction flange 9 in
the hood body outlet.
• Keep the pipe in position using clamps. The necessary material
is not supplied.
• Remove any charcoal anti-odour filters, if used.
EN
Hood body assembly
Connections
11a
Vr
9
ø 150
ø 120
1
18
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fpl 906

Table des Matières