5.

Maintenance

Level switches must be periodically (min. 1x annually) tested and cleaned.
Procedure:
1.
Loosen the flange connection and remove the switch.
2.
Check the float and mechanism for damage and contamination.
3.
Remove deposits and metal particles by means of suitable and approved methods. Care must be
taken to ensure that no mechanical damage occurs as a result of the cleaning.
4.
In the case of floats with protective bellows, the bellows must be removed before cleaning and should
be cleaned separately, both internally and externally.
5.
Inspect the float and mechanism for complete deflection, as well as for smooth and unrestricted
operation.
6.
In the event that it becomes necessary to replace individual components, please note that only original
spare parts, split pins, float, switch module, etc. may be installed.
7.
After completion of the cleaning / inspection work, the switch module must be checked for correct
function by means of simultaneous complete deflection of the float, followed by recording in the
inspection log book.
8.
In order to guarantee the absence of leaks between process vessel / float chamber, the flange gasket
must be replaced after each dismantling.
9.
After carrying out the inspection work, the device is re-assembled at the intended location.
Adjustment screws in the interior of the housing must not be adjusted!
6.

Replacement of the switch module

Defective switch modules must be replaced with new, works-tested units. In order that the complete type
designation can be stamped on the type plate, the complete designation of the existing switch must be
specified at the time of ordering. If a complete identification of the switch is not possible, then the manu-
facturer should be consulted before dispatching the complete device.
In case of uncertainty on any point, please contact the local Trimod Besta agent or the manufaturer.
Replacing the switch module
Important notes: The level switch does not have to be removed from the process vessel in order to
replace the switch module.
Procedure:
1.
Observe Chapter 1 "Safety instructions".
2.
Detach the hose or pipe screwed connection from the valve body.
3.
Remove socket head cap screws from housing with Allen key (5 mm).
4.
Carefully remove the switch module from the flange.
5.
Fit a new gasket on the flange and check that it is correctly seated.
6.
Place the replacement switch module (incl. gasket) on the flange and tighten the socket head cap
screws with the Allen key.
7.
Assemble the hose or pipe screwed connection in the valve body and check that it is seated correctly.
8.
Carefully allow the supply air (pressure) to build up.
7.

Fire protection

Trimod Besta level switches must be protected against external fire hazard.
8.

Disposal

Trimod Besta level switches are free of any asbestos-containing or otherwise hazardous materials. Disposal
must be carried out in an environmentally-friendly manner and in accordance with the local regulations.