5. Drain the condensed water of the pressure vessel
at the condensate outlet (3) on a daily basis.
CARE AND MAINTENANCE
Prior to all servicing:
Switch machine off. Disconnect the mains plug.
Wait until the device has stopped. Ensure that there
is no more pressure on the device and all used
compressed air tools and accessories.
Leave the device and all used compressed air tools
and accessories to cool down.
After all servicing:
Put back into operation and check all safety installations.
Ensure that there are no tools or similar at or in the
device.
Repair and maintenance work other than described
in this section must only be carried out by qualified
specialists.
Important information
Maintenance and test have to be planned and carried
out in accordance with the legal provisions in line with
the setup and mode of operation of the device.
Regulatory authorities may ask to view respective
documentation.
Regular maintenance
Prior to every start
– Check compressed air hoses for damage and replace,
if necessary.
– Check that all screw fittings are seated securely,
and tighten if necessary.
– Check connection cables for damage, and,
if necessary, have it replaced by a qualified
electrician.
Daily
– Drain the condensed water of the pressure vessel
at the condensate outlet (3).
Every 50 hours of operation
– Clean air filter (10) (see fig. 5)
– Check the oil level of the compressor at the
inspection glass (12), if necessary refill oil.
Every 250 hours of operation
– Clean air filter (10) or replace (see fig. 5).
Every 500 hours of operation
– Completely drain the oil at the oil outlet plug (13)
and replace.
Every 1000 hours of operation
– Have an inspection carried out in an authorised
English (Original Instructions)
DANGER
service centre. This significantly increases the
service life of the compressor.
Storage of device
1. Switch off the device and pull mains plug.
2. Depressurise the pressure vessel and all connected
compressed air tools.
3. Drain the condensed water of the pressure vessel
at the condensate outlet (3).
4. Store the device in such a way that unauthorised
persons cannot start it.
5. Do not place the device on its side. Oil might leak!
Do not store the tool outdoors or in damp
conditions without protection.
Danger of frost
Frost (< 5 °C) destroys the pump and accessories as
both always contain water! If there is a danger of frost
disassemble pump and accessories and store in frost-
free conditions.
REPAIRS
Repairs to power tools must be carried out by
qualified electricians only!
If you have Greenworks devices that require repairs, please
contact your Greenworks service centre.
ENVIRONMENTAL PROTECTION
The condensed water from the pressure vessel contains
oil residue and /or contaminations hazardous to the
environment. Dispose of the condensed water in an
environmentally-friendly manner using respective
collection sites!
Dispose of the old oil from the compressor in an
environmentallyfriendly manner using respective
collection sites. Observe national regulations on
environmentally compatible disposal and on the recycling
of disused machines, packaging and accessories.