Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6000-3560-0000-1XX 35600-2019 V101 11 ⁄ 2018
211x
PREMASGARD
® 
212x ⁄ 212x - SD
PREMASGARD
® 
D
Bedienungs- und Montageanleitung
Druck- und Differenzdruckmessumformer,
incl. Anschluss-Set, Kompaktform, einstellbar, kalibrierfähig,
mit Mehrbereichsumschaltung und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Pressure and differential pressure measuring transducers,
including connection set, compact form, adjustable,
calibratable, with multi-range switching and active output
F
Notice d'instruction
Convertisseur de pression et de pression différentielle,
y compris kit de raccordement, forme compacte, réglable,
étalonnable, avec commutation multi-gamme et sortie active
r
Руководство по монтажу и обслуживанию
Преобразователь давления измерительный и преобразователь
давления измерительный дифференциальный,
вкл. комплект соединительных деталей, компактное
исполнение, настраиваемый, калибруемый, с переключением
между несколькими диапазонами и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
Tel: +7(495)510-11-04
email:
zakaz@energometrika.ru
www.energometrika.ru
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
®
PREMASGARD
211x
PREMASGARD
®
212x
®
PREMASGARD
212x - SD

Publicité

loading

Sommaire des Matières pour Sensors PREMASGARD 211x

  • Page 1 D G F r 6000-3560-0000-1XX 35600-2019 V101 11 ⁄ 2018 211x PREMASGARD ®  212x ⁄ 212x - SD PREMASGARD ®  ® PREMASGARD 211x Bedienungs- und Montageanleitung Druck- und Differenzdruckmessumformer, incl. Anschluss-Set, Kompaktform, einstellbar, kalibrierfähig, mit Mehrbereichsumschaltung und aktivem Ausgang Operating Instructions, Mounting & Installation Pressure and differential pressure measuring transducers, including connection set, compact form, adjustable, calibratable, with multi-range switching and active output...
  • Page 2 D G F r 211x PREMASGARD ®  212x ⁄ 212x - SD PREMASGARD ®  Maßzeichnung PREMASGARD ® 211x Dimensional drawing Plan coté Габаритный чертеж ø4 ø6 M16x1.5 ohne Display without display sin écran без дисплея M16x1.5 mit Display with display avec écran с...
  • Page 3 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 Die kalibrierfähigen, kompakten Drucksensoren der Serien PREMASGARD ® 211x ⁄ 212x ⁄ 212x - SD sind mit 8 umschalt baren Messbereichen, 2 umschalt baren Ausgangssignalen (16 Geräte in einem) und optional mit Display ausgestattet und dienen zur Messung von Über-, Unter- oder Differenz drücken der Luft.
  • Page 4 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® PREMASGARD 212x - SD Druck- und Differenzdruckmessumformer (mit Schnappdeckel), Standard Druckbereich Typ ⁄ WG01 Ausgang Art.-Nr. (einstellbar) (einstellbar) (Druckanschluss unten) max. – 1000...+ 1000 Pa PREMASGARD ®...
  • Page 5 Bürdendiagramm ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® ® PREMASGARD 211x Bürdendiagramm PREMASGARD 211x Montageschema Bürdendiagramm PREMASGARD ® 212x 4...20 mA ® PREMASGARD 212x - SD zulässiger Bereich 110 Pa 110 Pa 110 Pa zulässiger Bereich 35 36 40...
  • Page 6 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® Schaltbild PREMASGARD 211x Anschlussbild PREMASGARD ® 211x PREMASGARD ® 212x ® PREMASGARD 212x ® PREMASGARD 212x - SD PREMASGARD ® 212x - SD min. max. Status-LED (DIP 6) I-Ausgang (ON) = orange 230V AC U-Ausgang (OFF) = grün...
  • Page 7 1 oder 10 Sekunden eingestellt werden. Durch eine höhere Filterzeit wird automatisch Anzeige im Display die Einschwingzeit des Sensors verlängert. Im Display wird in der 1. Zeile der Ist-Druck bis zur Messbereichsgrenze angezeigt. Es erfolgt eine automatische Umschaltung zwischen den Einheiten Pa und hPa (100 Pa = 1 hP).
  • Page 8 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Konfiguration und Nullpunktkalibrierung U - Variante I - Variante (MB: 0...+ xx Pa) (MB: 0...+ xx Pa) Nach erfolgreicher Nullpunktkalibrierung beträgt die Nach erfolgreicher Nullpunktkalibrierung beträgt die Ausgangsspannung (bei Mittelstellung des Offsetreglers) Ausgangsspannung (bei Mittelstellung des Offsetreglers) 0 V bei O Pa Druckdifferenz! 4 mA bei O Pa Druckdifferenz!
  • Page 9 Wichtige Hinweise Die Einbaulage ist beliebig. Der Spannungsausgang ist kurzschlussfest, ein Anlegen einer Überspannung am Spannungsausgang zerstört das Gerät. Die Druckbereiche (Messbereiche) sind auf dem Geräteetikett angeben. Bei Messdrücken außerhalb dieses Bereiches kommt es zu Fehlmessungen, zu erhöhten Abweichungen oder es kann zur Zerstörung des Druckmessumformer führen. –...
  • Page 10 These pressure transmitters have a pushbutton for manual zero point calibration and an adjustable offset. Applications of these pressure sensors are in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for monitoring filters, for level measurement or for triggering frequency converters.
  • Page 11 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® PREMASGARD 212x - SD Pressure and differential pressure measuring transducers (with snap-on lid), Standard Pressure range Type ⁄ WG01 Output Item No. (adjustable) (adjustable) (Pressure connectors on the bottom side) max.
  • Page 12 Load resistance diagram ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® ® PREMASGARD 211x Load resistance diagram PREMASGARD 211x Mounting diagram Load resistance diagram PREMASGARD ® 212x 4...20 mA ® PREMASGARD 212x - SD Admissible range 110 Pa...
  • Page 13 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® Schematic diagram PREMASGARD 211x Connecting diagram PREMASGARD ® 211x PREMASGARD ® 212x ® PREMASGARD 212x ® PREMASGARD 212x - SD PREMASGARD ® 212x - SD min. max. Status LED (DIP 6) I Output (ON) = orange 230V AC...
  • Page 14 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Configuration and zero point calibration The following configurations can be preset via Offset adjustment is done at a potentiometer on the circuit board within an adjustment range of ± 10 % of the device’s pressure range. DIP switches.
  • Page 15 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Configuration and zero point calibration U - variant I - variant (Range: 0...+ xx Pa) (Range: 0...+ xx Pa) After successful zero point calibration, the output voltage After successful zero point calibration, the output current is 0 V at 0 Pa pressure difference (with the offset knob is 4 mA at 0 Pa pressure difference (with the offset knob in central position)!
  • Page 16 General notes This device can be mounted in any position. The voltage output is short-circuit proof. Applying overvoltage at the voltage output will destroy this device. Pressure ranges are indicated on the device label. Applying measuring pressures beyond that range will cause mismeasurements and increased deviations or may destroy the device.
  • Page 17 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 Les capteurs de pression compacts étalonnables des séries PREMASGARD ® 211x ⁄ 212x ⁄ 212x - SD sont dotés de 8 plages de mesure commu- tables, 2 signaux de sortie commutables (16 appareils en un) et en option d'un écran et servent à mesurer les surpressions, les dépressions ou les pressions différentielles de l'air.
  • Page 18 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® PREMASGARD 212x - SD Convertisseur de pression et de pression différentielle (avec couvercle emboîté), Standard Plage de pression Type ⁄ WG01 sortie référence (réglage) (réglage) (prises de pression en bas) max.
  • Page 19 Load resistance diagram ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® ® PREMASGARD 211x Diagramme de charge PREMASGARD 211x Schéma de montage Load resistance diagram PREMASGARD ® 212x 4...20 mA ® PREMASGARD 212x - SD Admissible range 110 Pa...
  • Page 20 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® Schéma de raccordement PREMASGARD 211x Schéma de raccordement PREMASGARD ® 211x PREMASGARD ® 212x ® PREMASGARD 212x ® PREMASGARD 212x - SD PREMASGARD ® 212x - SD min.
  • Page 21 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Configuration et étalonnage du point zéro Les configurations suivantes peuvent être Le point zéro se règle par l’intermédiaire d’un potentiomètre sur la plaquette, effectuées au moyen de l’interrupteur DIP. selon une plage de réglage de ± 10 % de la plage de pression de l’appareil. Les curseurs ne nécessitent aucun outillage.
  • Page 22 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Configuration et étalonnage du point zéro variante U variante I (plage de mesure: 0...+ xx Pa) (plage de mesure: 0...+ xx Pa) Une fois le calibrage du point zéro effectué, la tension Une fois le calibrage du point zéro effectué, le courant de sortie (si le bouton offset est en position médiane) de sortie (si le bouton offset est en position médiane)
  • Page 23 Généralités La position de montage peut être choisie librement. La sortie en tension est isolée de la masse, l’application d’une surtension à la sortie en tension causerait la destruction de l’appareil. Les plages de pression (plages de mesure) sont indiquées sur l’étiquette signalétique de l’appareil. Le non-respect des dites plages de mesure entraînera des mesures erronées, des incertitudes de mesure plus élevées ou peut causer la destruction du convertisseur de pression.
  • Page 24 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 Компактные калибруемые датчики давления серии PREMASGARD ® 211x ⁄ 212x ⁄ 212x - SD имеют 8 перек лючаемых измерительных диапазонов, 2 перек лючаемых выходных сигналов (16 устройств в одном) и дисплей (опционально) и служат для измерения избыточного давления, разрежения...
  • Page 25 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® PREMASGARD 212x - SD Преобразователь давления измерительный и преобразователь давления измерительный дифференциальный, (с защелкивающейся крышкой), Standard Диапазон давления Тип ⁄ WG01 Выход Арт. № (настраиваемый) (настраиваемый) (Присоединительные...
  • Page 26 Load resistance diagram ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® ® PREMASGARD 211x Нагрузочная диаграмма PREMASGARD 211x Схема монтажа Load resistance diagram PREMASGARD ® 212x 4...20 мA ® PREMASGARD 212x - SD Admissible range 110 Pa 110 Pa...
  • Page 27 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD Rev. 2019 - V11 ® Схема подключения PREMASGARD 211x Схема подключения PREMASGARD ® 211x PREMASGARD ® 212x ® PREMASGARD 212x ® PREMASGARD 212x - SD PREMASGARD ® 212x - SD min. max. Status LED (DIP 6) I Output (ON) = orange 230V AC...
  • Page 28 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Конфигурация и калибровка нулевой точки При помощи DIP-переключателей можно Смещение настраивается при помощи потенциометра на печатной плате, выполнить следующие конфигурации. диапазон настройки составляет ± 10 % измеряемого прибором диапазона давлений. Управляющие...
  • Page 29 ® PREMASGARD 211x ⁄ 212x ⁄ 212x - SD | Конфигурация и калибровка нулевой точки Вариант U Вариант I (диапазон измерения: 0...+ xx Па) (диапазон измерения: 0...+ xx Па) После успешной калибровки положения нуля выходное После успешной калибровки положения нуля выходной ток напряжение...
  • Page 30 Важные указания Установочная длина может быть любой. Выход напряжения защищен от короткого замыкания, приложение завышенного напряжения к выходу напряжения выводит прибор из строя. Диапазоны давлений (диапазоны измерения) указаны на этикетке/табличке прибора. Попытка измерения давления вне этих пределов ведет к погрешностям, повышенным отклонениям или может стать причиной выхода из строя измерительного преобразователя давления. –...
  • Page 31 D G F r 211x PREMASGARD ®  212x ⁄ 212x - SD PREMASGARD ®  ® Maßzeichnung PREMASGARD 212x - SD Dimensional drawing Plan coté Габаритный чертеж ø 4 ø6 mit Schnappdeckel M16x1.5 with snap-on lid avec couvercle emboîté с защелкивающейся крышкой...
  • Page 32 D G F r Zubehör Accessories Accessoires Принадлежности Maßzeichnung ASD - 06 Maßzeichnung ASD - 07 Maßzeichnung DAL - 01 Dimensional drawing Dimensional drawing Dimensional drawing Plan coté Plan coté Plan coté Габаритный чертеж Габаритный чертеж Габаритный чертеж ø16 ø25 ø6 Federn Springs...

Ce manuel est également adapté pour:

Premasgard 212xPremasgard 212x-sd