Maintenance - Technical Data - Quick CHC 1102 M Manuel De L'utilisateur

Masquer les pouces Voir aussi pour CHC 1102 M:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE
The chain counter does not require any particular maintenance. To assure top performance, check the
cables and electrical connections once a year.
Clean the chain counter with a soft rag dampened in water. Do not use chemicals or harsh products to
clean the chain counter.
TECHNICAL DATA
MODELS
OUTPUT CHARACTERISTICS
UP/DOWN contacts current
INPUT CHARACTERISTICS
Supply voltage (1)
Current absorbed when idling (2)
Maximum current absorbed (3)
AMBIENT CHARACTERISTICS
Operating temperature (4)
Degree of protection (5)
GENERAL
Communication interface
Clock battery
EMC class
CASE
Weight
Dimensions (WxHxD)
62.2 x 185 x 49.4 mm
(1) The chain counter can reset itself if the voltage is less than 9 Vdc.
(2) Typical value with back-lighting and torch off and windlass not on.
(3) Typical value with back-lighting on at highest level and windlass on.
(4) With temperatures below 0°C the crystals in the LCD slow down.
(5) Except for the area where the electric contacts are connected (IP 00).
®
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
CHC1102M GB F - REV005B

MAINTENANCE - TECHNICAL DATA

165 mA + current used by solenoid/reversing solenoid unit
CAN BUS with differential transceiver
EN 60945 - FCC Part 15 Rules 47
CHC 1102 M
4A max
from 9 to 30 Vdc
40 mA
-20 ÷ +70 °C
IP 67
CR2032 (3Vdc)
750 g
62.2
49.4
59.1
41.6
GB
33