Flow Chart - Menu; Technicals Specifications - LA NORDICA MODULO ALL INCLUSIVE Instructions Pour L'installation, L'utilisation Et L'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. FLOW CHART - MENU

1
2
3
T4
T3
WARNING: the parameters in the technical menu should never be modified. Such operation must only be performed by an Authorised La NORDICA
S.p.A. Service Centre.
La NORDICA S.p.A. is not liable for product malfunctions due to the parameters in the technical menu being modified without authorisation.

11. TECHNICALS SPECIFICATIONS

SPECIFICATIONS
POWER SUPPLY
POWER INPUT
MAX PROBE TEMPERATURE
OPERATING TEMPERATURE
OVERALL DIMENSIONS
CONTAINER
INDEX OF PROTECTION
PUMP CONTROLLED
VALVE CONTROLLED
PUMP CONTROL RANGE
VALVE CONTROL RANGE
SIGNALS
PUMP ON
3-WAYS VALVE ACTIVE
OUTLET TEMPERATURE
EXCESS WATER TEMPERATURE ALARM / PROBE DAMAGED
ANTI-BLOCK
FROST PROTECTION
DOMESTIC HOT WATER
COMFORT function
14
4
5
6
T2
T1
LANGUAGE
BUZZER
ON - OFF
SET DEGREES
°C- F
DISPLAY
10 - 100%
TECHNICAL
SETTINGS
230 V~ +15-10% 50/60 Hz
Max 2VA
120°C
0 – 60°C
120x74x51 (3 gang switch box)
RAL9001 faceplate, BLACK frame
IP40
Max 400 W
Max 400 W
10 – 78°C (C1 default 75°C - C2 default 65°C)
10 – 78°C
Led 4 - 5
Led 6
Ramp 0 - 100°C resolution 1°C
Led 1 with audible signal (selectable)
Led 1
Led 1
Led 3
Led 2
MODULO ALL INCLUSIVE
ITALIANO
ENGLISH
FRANCAIS
ESPANOL
DEUTSH
SETTINGS FACTORY
CODE ---
7095520 - IT-EN-DE-FR

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Modulo all inclusive 2.0

Table des Matières