38
en | Connection compartment
4.2
Mode selection
Modes 1 to 9 can be selected by operating switches 1 to 5 of
the 5-digits micro switch S3.
CAUTION!
After selecting the mode, disconnect the power supply and
connect it again.
Mode Description
1
Normal mode
2
Normal mode, with the red LED
deactivated at battery-low indication
3
Dementia mode
4
Dementia with Accompany mode
5
Remote control
6
Open receiver
7
Open receiver with reduced range
8
Extended N46 (from SW 1.10 on)
9
Dual channel receiver (from SW 1.10 on)
NOTICE!
Factory setting is all switches set to off.
4.2.1
Mode indication after power on
–
–
F.01U.139.675 | V1.4 | 2015.08
When the power supply is connected to the LE10 Radio
Receiver, the green LED will light up permanently for 2
seconds. Afterwards, the device will display the current
mode through the green LED, by blinking as many times as
the number of the mode. The green LED will then light up
permanently.
Example: In mode 8, the green LED will blink 8 times.
When changing the mode, all programmed transmitters will
be deleted.
User Manual
LE10 Radio Receiver
Switch number
1
2
3
4
off
off off off off
on
off off off off
off
on
off
off off
on
on
off off
off
off on
off off
on
off on
off off
off
on
on
off
on
on
on
off
off
off off on
5
off
off
off
off
TeleAlarm