Schéma Ventilation Directe; Évent De Toit - Enviro 6G50100PDVH02 Manuel D'utilisation

Table des Matières

Publicité

SCHÉMA VENTILATION DIRECTE
Figure : 20
MAXIMUM 2,5 cm
AU DRAIN
Figure : 22
ÉVENT DE TOIT
ÉVACUATION
MINIMUM 15,2 cm (6 po)
ARRIVÉE
12" MINIMUM CLEARANCE ABOVE HIGHEST
DÉGAGEMENT MINIMUM DE 30,5 cm (12 po) AU DESSUS
ANTICIPATED SNOW LEVEL
DU PLUS HAUT NIVEAU DE NEIGE ANTICIPÉ
TOIT
NIVEAU DU SOL
VENTILATION À PAROI
24" MINIMUM SEPARATION. EXHAUST
MUST BE AT SAME LEVEL OR ABOVE
NIVEAU OU AU DESSUS QUE LE TERMINAL
MINIMUM
INTAKE TERMINAL.
2,5 cm (1 po)
(1 po)
DÉGAGEMENT MINIMUM DE 30,5 cm
(12 po) AU DESSUS DU PLUS HAUT
NIVEAU DE NEIGE ANTICIPÉ OU DU SOL
PURGEUR
(EN
OPTION)
VENTILATION CONCENTRIQUE
LATÉRALE
SÉPARATION MINIMUM DE 61 cm (24 po)
L'ÉVACUATION DOIT ÊTRE AU MÊME
D'ENTRÉE
Figure : 23
31
12" MINIMUM CLEARANCE
DÉGAGEMENT MINIMUM DE 30,5 cm
ABOVE HIGHEST ANTICIPATED
(12 po) AU DESSUS DU PLUS HAUT
SNOW LEVEL
NIVEAU DE NEIGE ANTICIPÉ
TOIT
NIVEAU DU SOL
Figure : 21
IMPORTANT : LE POINT
D'ENTRÉE DOIT FAIRE FACE
VERS LE HAUT
MAXIMUM 2,5 cm (1 po)
NIVEAU DU
SOL
VENTILATION
CONCENTRIQUE
DÉGAGEMENT MINIMUM DE
30,5 cm (12 po) AU DESSUS DU
PLUS HAUT NIVEAU DE NEIGE
ANTICIPÉ OU DU SOL