Clean the recovery tank after every use. Use a fresh water hose to rinse out the recovery tank. Be careful not to spray
water into the float shut-off mechanism.
NOTE
If you are storing the machine for any period of time, always leave the clear recovery tank lid off the tank so the
tank can dry completely and smell fresh.
Replace the drain hose plug tightly as soon as you are done draining the tank.
DRAINING THE SOLUTION (CLEAN) TANK
NOTE
Any time scrubbing operation is completed, the solution tank should be drained and cleaned.
Pull down on the clear tube (back left of the machine) to remove it from the hose barb. This will allow the solution to
flow freely into a bucket or floor drain.
Rinse the solution tank with clean water after every use. This will help prevent chemical buildup and clogging of the
solution lines.
With clean water in solution tank, turn machine power on, solution switch "on" and pull the operating triggers. This will
allow the clean water to flush through and clean the solution plumbing.
Once tank is rinsed, flushed and drained, reconnect the clear tube to the hose barb. Be sure the tube is pushed all the way
up on the hose barb.
BATTERY CHARGING
NOTE
For the best machine performance, keep batteries charged at all times. Do not let them sit in a discharged
condition.
NOTE
If the machine has an optional battery charger installed, the machine cannot operate if the charger is not on
board. In case of battery charger malfunction, contact an authorised Service Center.
CAUTION!
Use only approved chargers with the following specifications:
Automatic shut off circuit
Deep cycle charging
Output current of 25-35 Amps
Output voltage of 36 Volts
CAUTION!
Batteries are dangerous! Batteries emit hydrogen gas and an explosion or fire can result. Keep sparks and fire
away from batteries at all times. When charging the machine, make sure the battery compartment is left open.
Place charge and machine in a well ventilated area.
Turn machine off.
Open recovery tank up, exposing battery compartment .
Check fluid level in each battery cell. Do not charge batteries unless fluid is slightly covering the battery plates. Do not
overfill the batters. Overfilling may cause the batteries to overflow during charging due to expansion. Replace the caps
prior to charging.
Plug approved charger into grounded wall out let before plugging the charger into the machine.
Plug charger into red charger receptacle located in the front left of the battery compartment.
Flip up the recovery tank "Kick stand" and gently lay the recovery tank down until it rests on the stand.
The battery charger will automatically begin to charge the batteries, and it will automatically shut down once the batteries
are fully charged.
Upon completion of charging, first unplug the charger from the wall outlet, and then disconnect the charger from the
machine.
Check the battery level after charging is complete. If fluid level is low, add distilled water to bring the fluid level up to the