Rollotec - Berker RolloTec Mode D'emploi

Masquer les pouces Voir aussi pour RolloTec:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Connection of a
Example for 2 blind/shutter motors:
Insert
pushbutton
The automatic and manual control of both motors is ensured 'centrally' by insert
in conjunction with a
for both motors in parallel so that the connected motors will run up or down together
(e.g. after central UP command in the morning and central DOWN command in the
evening for all blind/shutter motors connected).
The motors M1 (insert
manually from the
Further 24V inserts can be added as shown in the schematic.
Important: As long as an UP signal is present on the extension input with terminal
'1'
device itself or by automatic control.
30
®

RolloTec

insert 'Komfort' for DC drives
'central control'.
with
RolloTec
®
clock
timer; inserts
and
with
RolloTec
or
RolloTec
®
pushbutton.
RolloTec
®
clock
timer. The switching commands are evaluated
) and M2 (insert
) can, in addition, also be operated
RolloTec
®
radio-control pushbutton
or from a
RolloTec
and terminal '2'
, the blind/shutter cannot be operated manually on the
®
radio-control
®
pushbutton.
GB
Connection of
RolloTec
®
insert 'Komfort' for DC drives
2 groups
Example for 6 blind/shutter motors
Central control is ensured by the 24 V insert in conjunction with a
timer. Two groups comprising three 24 V inserts respectively with a
control pushbutton
or with a
RolloTec
®
pushbutton
can be operated locally. The
inserts for motors M1 and M4 have a leading function for the respective group. If
these motors are activated, all the motors of the complete group will follow suit.
Further 24V inserts can be added as shown in the schematic.
Important:
As long as an UP signal is present on the extension input with terminal '1'
terminal '2'
, the blind/shutter cannot be operated manually on the device itself or
by automatic control.
To avoid overloading, the power ratings of the supply units, motors (see manufacturer's
instructions) and inserts must be observed (see Technical characteristics).
for central control with
®
RolloTec
clock
RolloTec
®
radio-
and
31