Télécharger Imprimer la page

Storage; Dismantle And Store; Faults And Remedial Measures; When Something Isn't Working - variolux V-GP 900 Manuel D'utilisation

Publicité

Gartenpumpe_322891_396630.book Seite 43 Montag, 7. Februar 2011 8:50 08
– Insert cleaned filter cartridge into the filter housing.
– Screw filter housing back down. Ensure proper location of the seal!

Storage

If there is danger of frost, dismantle the device and accessories, clean and store them in a place
protected from frost.
Danger of damage to the device!
Frost will damage the device and accessories, since they always contain water!
Attention!

Dismantle and store

1. Turn off the device, unplug the mains plug.
2. Open pressure line (turn on water spigot or nozzle), allow water to completely run off.
3. Completely empty the pump by unscrewing the water drain plug (6) on the underside of the
pump.
4. Dismantle the suction and pressure lines from the device.
5. Store device in a frost-free room (at least 5 °C).

Faults and remedial measures

When something isn't working...

Risk of injury!
Improperly performed repairs can lead to the device not functioning safely. This
Danger!
endangers yourself and your environment.
In many cases small defects can lead to a malfunction. You will usually be able to deal with these
yourself. Please refer to the table below before contacting your local OBI market. This may save
you a lot of effort and quite often money.
Error/Fault
Pump does not work.
Cause
No power supply?
Motor overheats due to high
liquid temperature?
Motor overheats due to sealed
ventilation slots?
Residual current protection
switch (FI-switch) activated?
Motor defective?
322891 / 396630 V_01/02/2011
Storage
Remedy
Check the cable, plug, and the
fuse.
Eliminate cause of overheat-
ing.
(max. liquid temperature
► Technical data – p. 45)
Switch on FI-switch. If it hap-
pens again contact the electric
service partner.
Contact your local OBI store.
GB
43

Publicité

loading

Ce manuel est également adapté pour:

V-gp 1300