Cleaning programs
S1
5-minute flush interruption
To clean the urinal manually, the flushing program is paused for five minutes,
following which a main flush is activated. The system then returns to the
preset flushing program.
S2
Activate main flush
A main flush is activated, and then the system returns to the preset flushing
program.
S3
Interval cleaning
Flushing is paused for 2 minutes to let the descaler take effect, and then within
a 10-minute period the urinal is flushed 5 times (one short flush every 2
minutes). The last of the 5 flushes is a main flush. Finally, the system returns
to the preset flushing program.
04 English
200 S
200 W
200 S D
200 W D
45