9. Disposal

• Brass union and nut
• NBR seal ring
• High grade synthetic material check valve cartridge
• NBR lip seal ring
• High quality synthetic material test plug
Observe the local requirements regarding correct waste
recycling/disposal!

10. Troubleshooting

Disturbance
No or too small water flow rate
Rise in pressure in the prepressure sectionNot sealing properly in the prepressure
Beating sounds
11. Spare Parts
No. Description
1
Union seal washer
(10 pcs.)
2
Blanking plug with O-
ring R1/4" (5 pcs.)
3
Check valve cartridge
Honeywell GmbH
Cause
Stop valve in front of or below the check
valve is not fully opened
Valve cone jams in the guide
section
Sealing surfaces soiled or worn
The check valve is over-dimensioned
Dimension Part No.
/
" -
/
"
0901444
1
3
2
4
1"
0901445
1
/
"
0901446
1
4
1
/
"
0901447
1
2
2"
0901448
S06K-1/4
/
"
2166200
1
2
/
"
2110200
3
4
1"
2164400
1
/
"
2164500
1
4
1
/
"
2164600
1
2
2"
2164700
GB
Remedy
Open shutoff valves
Replace the valve cone
Replace the valve cone and the lip sealing
ring
Clean the sealing elements, replace if
necessary
Call Technical Customer Service
5