Air Outlet Selection - Mitsubishi Electric MFZ-KA25VA Notice D'utilisation

Masquer les pouces Voir aussi pour MFZ-KA25VA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT
Movement of the horizontal vane
When to use ?
Select (AUTO) for most
Horizontal vane position (1) is set.
situations.
I Recommended air
flow direction is
automatically set.
I Swing operation is
not used.
Vertical air flow (Does not blow directly
on individuals in room)
Select the air flow
Water may condense and drip from
direction to suit your
the horizontal vane if the air
personal preference.
conditioner is operated continuously
I The range displayed
using the down horizontal vane
on the remote
positions (3) – (5). To prevent this, the
controller and the
horizontal vane automatically moves
(1)
actual operation
to position (1) after 30 minutes to 1
range of the
hour of air conditioner operation. To
horizontal vane may
return to the previous setting, press
differ.
(2)
the
button on the remote
I The vane does not
controller again to select the position.
move to horizontal
position in COOL
(3)
and DRY modes.
After approximately 30
minutes to 1 hour
(4)
(5)
When positions
(3)–(5) are
selected
Select (SWING) for
The horizontal vane moves
swing operation.
intermittently between positions (1)
I The horizontal vane
and (4).
moves intermittently
The horizontal vane stops for a brief
so that the air does
period at positions (1) and (4).
not blow directly on
an individual in the
room for too long.
NOTE:
• Adjust the AIR FLOW direction using the remote controller. Moving the horizontal vane manually can cause trouble.
• When the operation mode changes in "
(AUTO)" mode, the horizontal vane is automatically changed to the position
in each mode.
• The horizontal vane automatically moves in certain intervals to determine its position, and then it returns to the set
position.
8
COOL/DRY
HEAT
When the air outlet selection switch is
set to blow out air from the upper and
lower air outlets, position (5) is set.
When the air outlet selection switch is
set to blow out air from the upper air
outlet only, position (3) is set.
The horizontal vane operates as de-
scribed below to prevent air from blow-
ing directly on individuals in the room.
When heating operation starts or dur-
ing defrosting operation, the air flow is
reduced and the upper air flow direction
is set to prevent cold air from blowing
directly on individuals in the room.
Vertical air flow
(Does not blow
directly on
individuals in room)
The horizontal vane moves to the set
position once warm air blows from the
indoor unit.
Set air flow direction
Position (1)
The horizontal vane moves intermit-
tently between positions (2) and (4).
The horizontal vane stops for a brief
period at positions (2) and (4).
I
To change the horizontal direction of the air flow, move the vertical vane manually.
• Change the direction of the vertical vane (upper), hold-
ing the tabs on the vane.
• Adjust the vane before operation starts.
Since the horizontal vane moves automatically, your fingers may be caught.

AIR OUTLET SELECTION

With this function, air comes out simultaneously from the upper and lower air outlets so that the room
can be cooled or heated effectively. This function is set using the switch behind the front grille of the
indoor unit. (This function is available in cooling and heating operation.)
How to set to blow out air from the upper
and lower air outlets:
I
Set the air outlet selection switch to
Air blows out automatically from the upper and lower air out-
lets as shown in the table below.
NOTE:
Set the air outlet selection switch to the end. Otherwise, air outlet cannot be selected as intended.
Description of operation
Operation
COOL
Air
flow
Upper air flow
Upper and lower air flow
Room temperature
Room temperature is
and set temperature
close to set tempera-
Conditions
are different.
ture, or the air
conditioner has
operated for 1 hour.
• Be sure to keep the area around the damper of the lower air outlet free of any objects. If any objects block the normal
operation of the damper, the left operation indicator lamp may blink.
• Change the direction of the vertical vane (lower), holding
the vane.
Always adjust the vane when the damper is open. Opening the
damper forcibly with hands can cause damage or malfunction.
How to set to blow out air from the upper
air outlet only:
I
.
Set the air outlet selection switch to
DRY
HEAT
Upper air flow only Upper and lower air flow
Air flow temperature
Air flow temperature
is high.
is low.
(During defrosting
operation, start of
operation, etc.)
.
Upper air flow

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mfz-ka35vaMfz-ka50va

Table des Matières