WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.

Make Gas Connection

3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
No appliance
below cooktop
A
B
C
D
E
F
G
H
I
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint
compound.
D. Adapter (must have ½"
male pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint
compound.
H. Manual gas shutoff
valve
I. ½" or ¾" gas pipe
Wall oven installed below cooktop
A
B
C
D
E
F
G
H
I
J
K
A. Manifold entrance
B. ³⁄₈" elbow
C. Use pipe-joint compound.
D. Adapter (must have ³⁄₈" male pipe
thread)
E. Flexible connector (pass through wall
between cabinets)
F. Adapter (must have ³⁄₈" male pipe
thread)
G. Use pipe-joint compound.
H. Appliance pressure regulator
(supplied)
I. ½" or ¾" gas pipe
J. Manual gas shutoff valve
K. ½" or ¾" gas pipe