not be connected well, but the machine is working in the condition of continuing dehumidifying. 
9、TIMER INDICATOR—Timing indicator lamp: Indicates the setting time to switch off. 
Operation                                                                                                             
After getting through the power, all the LED indicator lamps on PCB board are lighting 1 second and the buzzer 
is warning 3 times. 
1、 (POWER) ON/OFF button: When press it first time, the buzzer will warn one time, the machine is under the 
continuing dehumidifying mode, continuing dehumidifying indicator and power ON/OFF indicator 
(green light) will light. When press it second time, it will power off. The buzzer will warn when switch 
off. 
  2、 (HUMIDITY)Humidity setting button: When pressing first time, it will be transformed from continuing 
dehumidifying to setting humidity 40%RH and the indicator lamp will light; When press it    second 
time, it will be transformed to 50%RH;Press three times to 60%RH;Press four times to continuing 
dehumidifying.   
3、 (TIMER)Timing button: Press it first time to make it transferred to timing operating, setting time "2H"; 
Press second time to set time 4H; Press three times to set time 8H;Press four times to cancel the 
timing switch off. 
  4、Water full function: If the water tank is full, the switch of water tank will be cut off, compressor and fan 
motor stop working and their corresponding indicator lamp will be crushed out, only the water full 
indicator lamp(WATER FULL)  is lighting and buzzer is warning 10 times at the same time.   
5、Compressor protection function: After the compressor stop working, it can not be started up within 3 
minutes.   
 
 
 
 
    Draining equipment                                                                                                         
 
 
 
 
GB 
 
—— When the water tank is full: 
——Warning signal 
——Compressor stop working automatically, and machine stops dehumidifying。 
——Empty the water, then put back, and the compressor will be start up 
automatically, machine will continue dehumidifying; 
—— If you need the machine drain permanently, you can connect the drain pipe 
with water outlet, or it can not outlet water, and it will cause flood.   
—— Please put the drain pipe to the water outlet. 
——When you do not need the permanently drain equipment, please disconnect 
the drain pipe and make sure the water tank is put correctly. 

Publicité