Télécharger Imprimer la page

Etherma UT 40 Instructions D'installation Et D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

I N T R O D U C T I O N
By choosing ETHERMA, you have opted for a superb heating
solution. Thank you for your confidence in us. You have opted
for a competent partner with over 35 years of experience. You
will benefit from our continuous innovation, high-quality prod-
ucts and modern design.
We offer an extensive range of servic-
es to support you and can find a product solution suitable for
your individual requirements.
These instructions are intended to help you to use your ETHER-
MA quality product as effectively as possible. They provide
important information on safety, installation, use and main-
P R O D U C T O V E R V I E W
ETHERMA UT 40 is an electronic thermostat designed to give
energy-efficient frost protection to pipe work where thermal insu-
lation alone cannot protect pipes from freezing or being damaged
F E A T U R E S
› Simple setup & installation
› Includes 4 m long sensor
› Soft start function (gradual switch-on)
› Built in encapsulated sensor
› Temperature range 0 °C to +40 °C
› Solid state reliability
› Maintenance free
› IP 65 Ingress protection
P R O D U C T S E T U P
On page 6 are drawings with assembly instructions. Please use
these drawings for installation.
› Use the correct lead-through for the connection cable and
connect the cable to the correct terminals (POWER CON-
NECTION)
O P E R A T I O N
› Set the set temperature using the main knob in the range of
0 °C to +40 °C.
› When the ambient temperature drops below the set tempe-
rature, the load output soft-starts for 1 second before the
main output relay energises. The status LED will be lit.
E T H E R M A U T 4 0
tenance of the device. Therefore, please read the information
provided in these instructions carefully and keep for reference
in the event of questions at a later occasion.
The manufacturer shall not be held liable if these instructions
are not complied with. Devices may not be used improperly i.e.
for purposes other than the intended use.
The packaging of your high-quality ETHERMA product is made
from recyclable materials.
by ice. The units control heater tape or Infrared (IR) quartz lamps..
› Current capacity 20 A Max.
› Output & load fault detection
› Power & status LED indicators
› Place the probe in the correct position on the cable (not too
tight on the heating cable). Fix it with tape or tie rap.
› Use the correct lead-through for the heating cable and con-
nect it to the correct terminals (HEATING)
› When the ambient temperature is equal to or greater than
the set point temperature, the load output switches off. The
status LED will be off.
5

Publicité

loading