Prior to installation
Do not connect the appliance to the
mains until the installation is fully complete.
Circulating-air mode
❑ With activated carbon filter if exhaust-air
mode is not possible.
❑ The air purified by an additional
activated carbon filter is conveyed back
into the room.
❑ For insertion of the activated carbon
filter see Instructions for use.
❑ If the extractor hood is switched from
exhaust-air mode to circulating-air mode,
the exhaust-air opening must be sealed to
prevent a hazardous situation (see
optional accessories in the Instructions for
use).
Electrical connection
The mains power supply must correspond to
the rating indicated on the plate situated
inside the hood. If provided with a plug
connect the hood to a socket in compliance
with current regulations and positioned in an
accessible area. If it not fitted with a plug
(direct mains connection) or if the plug is not
located in an accessible area apply a bi-
polar switch in accordance with standards
which assures the complete disconnection of
the mains under conditions relating to over-
current category III, in accordance with
installation instructions.
Before re-connecting the hood circuit to
the mains supply and checking the efficient
function, always check that the mains cable
is correctly assembled.
If the connecting cable for this appliance
is damaged, the cable must be replaced by
the manufacturer or his customer service or
a similarly qualified person in order to
prevent serious injury to the user.
Before carrying out repairs, always
isolate the appliance.
Length of the connection cable: 1.5 m.