Kenmore 106.8955 Guide D'utilisation Et D'entretien page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Water Supply Line
A. ¹⁄₄" copper tubing
B. Cable clamp
C. ¹⁄₄" compression nut
Drain Pump Installation
NOTE: Do not kink, smash or damage tubes or wires during
installation.
1. Unplug ice maker or disconnect power.
2. Remove rear panel. See "Rear Panel" illustration for 5 screw
locations. Pull rear panel away from the drain tube and
discard.
Rear Panel
A. Screw locations
3. Remove the old drain tube and clamp attached to the ice
maker bin.
NOTE: Discard old drain tube and clamp.
4. Install new drain tube ( ⁵⁄₈ " ID x 5 ¹⁄₈ ") from ice maker bin to
drain pump reservoir inlet using new adjustable clamps. See
"Drain Tube" illustration.
NOTES:
Do not kink.
Trim tube length, if required.
8
A
B
B
C
D
C
E
D. Ferrule (sleeve)
E. Ice maker connection
A
A
Drain Tube
A. ⁷⁄₈" adjustable hose clamp
B. Drain tube (ice bin to drain pump)
5. Install vent tube ( ⁵⁄₁₆ " ID x 32" [81 cm]) to drain pump
reservoir vent. Use one ⁵⁄₈ " small adjustable clamp, supplied.
See "Parts Locations" illustration.
NOTE: Do not install household drain tube at this time.
Parts Locations
G
A. Vent tube
B. ⁵⁄₈" hose clamp
C. Drain pump discharge tube
D. Drain pump
6. Remove power cord clamp and ground screw attached to
ice maker power cord, which is mounted to the unit base.
See "Parts Locations" illustration.
NOTE: Clamp and screw will be reused.
7. Slide drain pump into the ice maker base on the right side.
The pump mounting tab should slip into the rectangular slot
in the ice maker base. It will be necessary to tip the pump
slightly to slip into the slot. See "Drain Pump Mounting Tab
Slot" illustration.
A
B
C
D
C. ⁷⁄₈" adjustable hose clamp
D. Drain pump reservoir inlet
A
B
C
D
E
F
E. Ice maker unit power cord
F. #8-32 x ³⁄₈" pump mounting screws
G. Drain pump power cord, clamp
and screw

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

106.8959

Table des Matières