Télécharger Imprimer la page

CDVI KCPROXWLC Mode D'emploi page 3

Masquer les pouces Voir aussi pour KCPROXWLC:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
KCPROXWLC
Dual Technology Digicode
/Proximity reader
®
6] WIRING EXAMPLE: KCPROXWLC to INTBUSW Reader interface
KCPROXWLC
Red
12VDC
Black
0V
Brown
Buzzer command input
Green
Data 0
White
Data 1
Blue
Clock
Purple
Programming
Yellow
Green LED
Orange
Red LED
Orange
Yellow
White
Green
Blue
Red
Black
brown
Purple
For the
programming
KCPROXWLC
connect the
purple cable
with the black
cable.
Strike
Magnet
Varistor
Input voltage selection
Two different configurations,
are possible:
12VDC only
(As standard)
Cut the strap
12VAC or 24VDC
cdvi.com
4
cdvigroup.com
INTBUSW
Shielded
cable
Door contact (not used)
To other door controllers
Connect E and M
(INTBUSW)
INSTALLATION MANUAL
EN
KCPROXWLC
Dual Technology Digicode
Without jumper : without clock
With jumper : with clock
STAND ALONE MODE
TELACCESS
- Dipswitch address set up
- Dip4 = ON
DIP SWITCH adressing
1
2
3
4
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ST1 (Programming jumper) : Normal
/Proximity reader
®
INTBUSW (Reader controller)
Terminal block : Motherboard
V
Input voltage -
12
Input voltage +
1
Data O
2
Clock
3
Data 1
Terminal block : Motherboard
R
N/C contact eletromagnetic lock (+)
C
Common contact power supply (+)
T
N/O contact electric release
R
N/C contact alarm
C
Common
T
N/O contact alarm
+ ~ - Input voltage DC or AC, 12V or 24V
P1
Request-to-enter input
M
Common ( P1 et P2 )
P2
Request-to-enter input
E
Door contact, N/C (Door closed) and N/O (Door open)
L
Reader activation imput (N/O) reader enabled and (N/C) reader disabled
M
Common ( E and M ) or (E and L)
A
RS485 Bus (All the A must be connected together in daisy chain)
B
RS485 Bus (All the B must be connected together in daisy chain)
Terminal block - 3 points : Piggyback board
7
Buzzer
8
LED > Green color
9
LED > Red color
ONLINE MODE
- TERENA
- Address programming during installation
- Dip4 = OFF
Mode
Front plate
Reader 1
Reader 2
ST1 (Programming jumper)
Reader 3
Reader 4
Normal (As standard)
EN
Installation
cdvi.com
5
cdvigroup.com

Publicité

loading