Tool Indications And Warning Signals; Warning Tone Of The Battery - Kamikaze Volpi KV 100 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ElEctrical PolE PrunEr

17. tool indications and warning signals

17.1 indication of charger
LED
3
Green squares
2
Green squares
1
Green squares
1
Red square
Indication
Red
Green

17.2 Warning tone of the battery

Warning
note
Interval
1
time
second
2
times
second
3
times
second
4
times
second
short
4
note
second
10
times
second
long
1
note
seconds
Li-Battery
Battery capacity
80%-100%
50%-80%
30%-50%
Below 30%
Charger
Situation
Charging
Charging finished
Warning
Frequency
0,3
No repeat
0,3
10 repeats
0.3
10 repeats
0,3
10 repeats
0,1
No repeat
0.3
10 repeats
5
10 repeats
Voltage
34 V <Vcc ≤ 42 V
Vcc ≤ 34 V
Situation or Problem
Indicate: start up and shutdown, small
and big blade mouth switch.
Indicate: is charging or shear is not
connected well, please check if the
nuts at both ends of the shear and bat-
tery is connected firmly.
Indicate: open hall signal of stroke pla-
te faults. Send the shear to Customer
Assistance.
Indicate: closed hall signal of stroke
plate faults. Send the shear to Custo-
mer Assistance.
The battery is used up. Please charge
the battery soon.
The scissor has worked for 100,000 ti-
mes already. Please remove the front
cover, blade, pin, lead screw and
re-grease the connection joints.
Scissor has worked for 500,000 times,
and it should be inspected and main-
tained fully. Please contact your local
dealer for servicing.