Bartscher MX 250 Mode D'emploi page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Start
The impulse start is performed only by pressing the appropriate ON/OFF button:
operation only with pressed button
No power
In case of power supply failure or after disconnecting the device from the supply it may
be restarted after following the procedure of start-up after the power restoration or
connecting the device to the supply installation.
Inspection before start-up
Control
Make sure that:
-
there are no foreign objects
in the pot
Check the cleanness of:
- external parts of the device
- surfaces of equipment
-
internal parts of the device
Check the condition of:
- permanent protective
covers
-
device body
Check the operational
condition of:
- controlling/protective parts
-
control system.
Make sure that:
-
there are no strange noises
after start-up
Procedure
Visual inspection in order to make sure that there
are no foreign objects in the pot, like tools, towels,
etc., or any non-food products. Remove such
objects if found.
Before the operation of the device all surfaces of
mentioned parts must be inspected visually for their
cleanness.
In case of mould or other contamination clean the
parts according to section 6.2 "Cleaning".
All permanent covers must fulfil their functions.
Perform the visual inspection of all mentioned parts
in order to make sure that their internal surfaces are
not damaged. After noticing the first symptoms of
wear/damage the parts must be immediately
replaced. Contact the service company.
All systems must fulfil their designed functions.
Use the systems in such way that they operate in
the expected way.
The parts revealing the first symptoms of wear or
damage must be immediately replaced. Contact the
service company.
In case of noticing any strange noises during the
inspection, indicating e.g. seizure or mechanical
fractures, turn the device off immediately and contact
the service company.
- 27 -