C2- Wiring diagram
1
You can directly connect the monitor to your
electrical panel via a 15V DC 0,8A (minimum)
«rail DIN» transformer. Electrical knowledges
are necessary, in this case. Please contact a
professional.
BE CAREFUL : RESPECT THE POLARITY !
The wire with the gray strokes should be
positioned on the +.
The wire with the writes must be positioned
on the -.
7
Indoor monitor
2
A
B
S
Polarity free
0 to 50 m - 0,75 mm²
50 to 100 m - 1 mm²
1
B
2
A
1
2
A
B
Connect the shield
if the cable is shielded
1
2
S
S
Until two additional monitors for a total limit of distance of 100 m
220 V
After installing and test, place a transparent
acid free silicone seal at the top and on the
sides of the door station (not at the bottom)
to avoid any risk of infiltration.
Outdoor station
LK+
LK-
SW1
SW2
Additional
monitor 1
Additional
monitor 2
-
+
12V DC - 700mA