Block Diagram
Block Diagram
Gain and slope control
Gain and slope control
- Adjust the slope potentiometer on 0 dB.
- Adjust the gain potentiometer to the
required position.
- Now adjust the slope to increase the gain
at the end of the band.
NOTE :
The gain is always in the range of 10-16 dB.
Application
Application
- Distribution of CATV signal to 2 outputs.
CATV
Réseau câblé
Note :
When connecting one output only, load the second
output with 75 Ohms.
Products are subject to change without notice.
UNITRON n.v., Frankrijklaan 27, B-8970 Poperinge, Belgium
TEL +32 57 33 33 63
FAX +32 57 33 45 24
www.johansson.be
E-mail : sales@johansson.be
47-862 MHz
IN
Max. gain
16 dB
Min. gain
10 dB
47 MHz
7712
LED
GAIN
SLOPE
ATTENTION !
Do not open.
Live parts inside.
Ne pas ouvrir.
10dB
16dB
0dB
6dB
Risq ue de choc électri que.
23 0 V~ / 5 0 Hz
Pma x. : 7 VA
7712
CATV INDOOR AMPLIFIER
47-862 MHz
0402
R et u rn p a th 5 - 30 MH z
IN
OUT 1
OU T 2
Schéma de principe
Schéma de principe
5-30 MHz
OUT1
Réglages gain et pente
Réglages gain et pente
- Mettre le potentiomètre de pente sur 0 dB.
- Régler le potentiomètre de gain à la valeur désirée.
- Régler ensuite la pente pour augmenter le gain
en fin de bande.
Remarque :
Le gain est toujours compris entre 10 et 16 dB.
- Répartition du signal réseau câblé vers 2 prises.
Return path
Remarque :
Branchement d'une seule sortie, boucler la seconde
sortie avec 75 Ohms.
Les spécifications peuvent être modifiées sans préavis. 01/04
OUT2
Slope / Pente
0-6 dB
862 MHz
Récepteur câbl e
Voie de retour
CA TV receiver
TV 1
TV 2
R

Publicité