APPROPRIATE USE
The GAS SENSOR GX-SE is a sensor for town, natural and liquid gas and is used as an
accessory with the gas warning devices in our product range.The sensor may not be used
in areas with a risk of explosion.Another use of the device as described above is not autho-
rized.
TECHNICAL SPECIFICATIONS
Operating voltage:
Type sensor:
Humidity (ambient):
Operating temperature:
Storage temperaturer:
Service life:
Protection type:
Cable length:
Cable Ø:
Dimensions (HxWxD):
Data diagram Sensor
Gas type
CO
Methane
Propane (isobutane)
Ethanol (acetone)
8
5 V
catalyitc
5–90 % RH (non-condensing)
-10 °C / +50 °C
-20 °C / +70 °C
approx. 5 years
IP 20
2,5 m
3,5 mm
52x27x29 mm
Minimum concentration
no alarm triggered
<5000 ppm (0,5%)
<2000 ppm (0,2%)
<5000 ppm (0,5%)