3
Your Heating System
product Specification
Model name
Modes
Overall unit dimensions
Weight (empty)
Weight (full)
Plate heat exchanger
Flow temperature
Target temperature
range
Room temperature
Ambient *1
Guaranteed operating
range
Outdoor temperature
Control board
Electrical data
Booster heater
*1 The environment must be frost-free.
*2 Cooling mode is not available in low outdoor temperature.
5
EHSE-yM9EC
Heating
Cooling
Heating
Cooling
Heating
Cooling
Power supply
(Phase, voltage, frequency)
Power supply
3~, 400V, 50Hz
(Phase, voltage, frequency)
Capacity
3kW + 6kW
Current
Hydrobox
EHSE-MEC
Heating ONLY
950×600×360 mm (Height×Width×Depth)
62 kg
60 kg
72 kg
70 kg
25 - 60°C
—
10 - 30°C
—
0 - 35°C ( 80%RH)
See outdoor unit spec table
—
~/N, 230V, 50 Hz
—
—
13A
—
ERSE-yM9EC
ERSE-MEC
Heating and Cooling
63 kg
61 kg
73 kg
71 kg
5 - 25°C
NOT available
See outdoor unit spec table
(min. 10°C).*2
3~, 400V, 50Hz
—
3kW + 6kW
—
13A
—