Step 3 – Position the Enphase Engage Cable
The Engage Cable is a continuous length of 2.5 mm2 (12 AWG), outdoor rated
cable with integrated connectors for microinverters. These connectors are
preinstalled along the Engage Cable at intervals to accommodate PV module
widths. The microinverters plug directly into the connectors, and the Engage
Cable is terminated into the junction box that feeds electricity back to the system
AC disconnect.
a. Lay the Engage Cable along the route it will travel, positioning the
connectors so that they align with the PV modules.
NOTE: Many PV modules have a central stiffening brace. In these cases, do
not position the connector and microinverter at the exact center of the PV
module, but position the Engage Cable so that the connectors do not conflict
with the braces.
b. PV module widths vary by manufacturer. On the Engage Cable,
connectors are spaced at intervals to allow for the widest PV modules
compatible with Enphase Microinverters. If narrower PV modules are
used, it may be necessary to account for excess cable by adding a loop
of cable at suitable intervals.