3.2.- Assembly sequence:

1.- Check that the water pipe reaches the place where the shower is to be installed.
2.- Make sure that the ground is level and firm enough to anchor the shower with plugs and screws. If it is not, condition
it properly or install the special fasteners. (Fig. 17)
3.- Remove the packaging from the shower body (Fig. 8).
4.- Loosen the four screws and remove the back cover (Fig. 9).
5.- Anchor the body to the ground (Fig. 10).
6.- Remove the packaging from the shower arm and place it in position (Fig. 11).
7.- Connect the shower arm to the ¾" plug fixed in the support (Fig. 12).
8.- Loosen the nut, direct the arm forwards and tighten the nut leaving the arm fixed in this position. Fully tighten the
flexible hose connection (Fig. 13).
9.- To connect to the mains, cut the excess hose and connect with the "Performance" link (Fig. 14).
10. - Before placing the back cover, open the stopcock and check that the connections are properly sealed.
11. - Place the back cover by tightening the four screws (Fig. 15).
3.3. - Adjustment of the shower head:
At one end of the arm is the showerhead, which has an adjustment screw to control the shape of the water jet. (Fig.
16).
4. - MAINTENANCE
This product is manufactured using rust-resistant materials.
However, minimum care is required for optimum
preservation. The surface of the metal parts should be periodically cleaned with suitable products, preventing lime
deposits. Do not use abrasive products that may scratch the surface.
Attention:
Remember to check that connections are sealed before placing the back cover.
Check the pressure of the water reaching the shower. Excessive pressure may cause leaks in connections. If there is
not enough pressure, there will be insufficient water coming out of the shower. The recommended pressure range is
between 2 and 5 bar.

5. - SAFETY WARNINGS

If the shower is installed in an already existing swimming pool, bear in mind the location of the electricity supply or
electric apparatus in order not to infringe regulations and to avoid risks of electric shocks.
The shower is equipped with a screw at the base for connection to the equipotential circuit.