PREVENTIVE MAINTENANCE AND CLEANING
• Disconnect the hand dryer from the mains supply.
• Remove the 2 lower holding screws from the cover using the special key.
• Remove the cover and place it carefully on a cloth avoiding scratches and
scrapes.
• Clean the dust from the surface and the parts of the main card of the
electronic circuit. To do this, use a soft brush.
• Use the same brush to clean the motor surface, the fan, the air outlet and the
air inlet grille.
• With a soft cloth, clean the surface of the IR sensor closure screen and
remove any dust covering on its surface.
• Open the volute removing the safety screw and folding the closure clips and
clean the fan wheel and heating element of dust. Close the volute again, putting
in the closure clips and tightening the safety screw.
• Clean the dust from the perimeter of the base, especially the upper section.
• Assemble the cover, place the lower screws and connect the dryer once
again.
• Start up the machine repeatedly in order to expel remains of dust after the
cleaning process.
CLEANING OF CHROMED AND GOLD PLATED COVERS
For cleaning purposes only a wet cloth is to be used. Do not use any kind
of detergent, acids, lye, abrasives, hydrochloric acid, etc.
Take care not to damage or force any component.