Mounting
The assembly should be preferably prepared for rear ducting.
• Drill holes of 8 mm (5/16") in the wall, using the template supplied. Clean the
holes of the resulting dust and insert the plugs.
• Pass the power cables from the wall through the 22 mm (7/8") hole situated
beneath the connection board of the appliance.
• Screw the base of the appliance tightly to the wall ensuring the 4 silent-blocks
are correctly positioned.
• Enter the power cables into the inside space containing the terminal strip,
passing them through the entry hole.
• To reach the terminal strip the protective top should be opened.
• Connect the cables from the mains to their locations in the terminal strip. Once
the electrical connection has been made, close the protective cover again.
• Fit the metallic cover into the base, placing it from top to bottom with a certain
inclinations. Make sure the upper rib has entered in their location in the base.
• Place the lower screws, tightening with the specially supplied key.
Means for disconnection with contact separations at least 3 mm (0.12") must be
incorporated in the fixing wiring.
During the installation process, the protection areas should be considered
according to norm VDE 0100.
The hand dryer must only be installed on a closed surface (wall, partition or
similar)