Waeco PowerPack PC100 Manuel D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
PC-100-12P.book Seite 22 Freitag, 25. November 2005 4:00 16
PowerPack PC100
The high-pressure hose has a fitting at the end for car valves. Use the
adapter in the rear compartment for other valves.
➤ Attach the fitting to the valve and lock it, by pressing the black lever 90°
toward the hose (see Fig. 7, page 4).
➤ Switch the "Compressor" switch (see Fig. 3.4, page 3) to "ON".
✓ The pressure gauge (see Fig. 4, page 4) indicates the current pressure in
bar and PSI.
➤ Once the desired pressure has been reached, switch the "Compressor"
switch (see Fig. 3.4, page 3) to "OFF".
✓ The compressor is switched off.
➤ Pull off the fitting from the valve.
After 15 minutes of continuous compressor operation, switch the
device off for 15 minutes.
Otherwise the device may overheat and become damaged.
➤ After you have inflated the car tyres, check the effective pressure with a
calibrated air pressure gauge (e. g. at a petrol station).
6.3
Using the PowerPack PC100 as an air pump
You can use the PowerPack PC100 as an air pump to inflate large-volume
inflatable boats or air mattresses or to release air from them.
➤ Open the rear compartment and take out the plastic hose.
➤ Attach the hose end without additional fittings to connector 1 (see Fig. 8,
page 4), to inflate the object or ...
➤ Attach the hose end without additional fittings to connector 2 (see Fig. 8,
page 4), to inflate the object or release the air.
➤ Attach the proper fitting of the other hose end to the object you wish to
inflate or release air from.
At this end of the hose there are three different fittings that can be used
with the existing valve. The fittings can be inserted to each other.
➤ Switch the "Compressor" switch (see Fig. 3.4, page 3) to "ON".