LIVE PLU G CON N E CTOR
Do not use the supplied Direct Connect
leads to connect to live cables. Use the
Radiodetection Genny Live Plug Connector
or Live Cable Connector. Failure to do so
may result in injury or equipment damage.
Connection to live power cables
should only be undertaken by
qualified personnel.
The Live Plug Connector applies the Genny signal to a live domestic
power socket and, via the domestic wiring system, to the service and
supply cable in the street.
Connect the Live Cable Connector to the Genny4 accessory socket
and the mains power socket, then switch the Genny4 and the power
socket on.
NOTE: The Live Plug Connector provides protection to 250V AC.

Service and Maintenance

The C.A.T4 and Genny4 are designed to require minimal
recalibration. However, as with all safety equipment, it is
recommended that they are serviced and have their calibration
validated at least once a year using Radiodetection approved test
equipment. Radiodetection accepts no responsibility for service,
calibration or repairs carried out by non-authorised persons.
To check when the C.A.T4 is next due to be calibrated, squeeze
the trigger, then press the depth button until 'C' (Configuration)
is displayed. The display will now automatically step through the
following information: 'S' (software version), 'D' (day), 'M' (month)
and 'Y' (year).
E CE RT
All C.A.T4 models feature eCert, which provides a thorough test of
the C.A.T4 locating circuitry, and supplies a Radiodetection
Calibration Certificate when a positive test result is obtained.
NOTE: eCert does not perform a complete functional check or
check the mechanical integrity of the unit under test including
the operation of the controls and LCD screen.
20
To run an eCert test, the C.A.T4 should be connected to an internet-
enabled PC on which the C.A.T Manager software is installed.
Additional purchase may be required contact Radiodetection for
more details.
R E PLACI N G BATTE R I E S
Do not mix new and old batteries or different types of
batteries, as this may cause them to overheat.
C.A.T4
To replace batteries, open the access cover using a
screwdriver or coin. Use two LR20 (D-cell) alkaline
batteries or equivalent NiMH rechargeable batteries.
Genny4
To replace batteries, open the access cover using
a screwdriver or coin. Use four LR20 (D-cell)
alkaline batteries.
PR OD U CT S PE CI FI CATI ON
Operating temperature range
Environmental protection
Depth accuracy
Horizontal GPS Position Accuracy* 3m CEP (Circular Error Probable)
Batteries
Unit weight
*gC.A.T4 models only.
The C.A.T4 and Genny4 with optional accessories have been designed
to locate buried utilities. Do not attempt to use for other purposes.
C.A.T4 and Genny4 products are manufactured in the U.K. under
ISO9001 certified conditions.
-20°C to +50°C (4°F to 122°F)
IP54
Line: ± 5% tolerance from 0.1m
(4") to 3m (10ft)
Sonde ("Mouse"): ± 5% tolerance
from 0.1m (4") to 7m (23ft)
C.A.T: 2 × Alkaline or NimH
D-cells (LR20)
Genny: 4 × Alkaline D-cells
(LR20)
C.A.T4: 2.3 kg
(including batteries)
Genny4: 2.7 kg
(including batteries)