9.
10. Turn off the appliance after every use.
WARNING:
Frost will damage the product beyond repair and is not covered by the warranty.
In order to prevent freezing damage: drain the water from the appliance after
every shower by opening the pressure relief valve K counter clockwise.
After draining the water close valve K again.
Do not use the appliance when there is strong wind (only use at <3 beaufort wind
force)
WARNING:
Only use approved gas tubes.
Only use gas tubes between 60 and 150 cm. with a diameter between 8 and 12
mm.
Check the gas tube every 3 months for cracks or leakage. Immediately replace if
any cracks or leakages are found.
NEVER cover the appliance!
Keep inflammable, volatile and/or explosives away from the appliance.
Do not use the water from the appliance as drinking water!
In case of any abnormal burning (smoke, yellow flame, unstable flame etc) stop
the use and contact your local dealer.
Do not touch any part of the Appliance during or short after use as the body
of the appliance might be hot. Only the turning knobs B and H and the on/off
button M.
SWITCH OFF AND DISCONNECT
Additional instructions for disconnecting the hot water geyser in the correct
order to prevent (water) damage:
1.
2.
3.
4.
5.
6.
4
56
When Button M is in on position "1" and there is sufficient gas and water
flow than the appliance will ignite automatically. During the ignition phase
the light C will light up. The light C will extinguish again when the flames are
in full operation.
To turn off the device, close the gas container and close the water tap. Switch
button M to the "0" position.
Turn off the power switch and remove the batteries.
Close the gas bottle and then disconnect the gas pipe.
Turn off cold water supply tap.
Empty the spray head and the water hose (e.g. in a bucket).
Disconnect the cold water supply hose and disconnect the hot water hose
(towards the spray head). Allow the device to drain for a while and then
mount the sealing caps back on the pipes.
CAUTION: the device may still contain water. When disconnecting the cold
and hot water pipe, this water will flow out!