Guarantee Certificate - Gnosjo 1460.000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
GB
E N G L I S H
Models with electronic thermostat 230V.
Lead with earthed plug. * (night economy)
1460.000 - 1467.000 (Fig. 4, alt. 4)
*
1480.000 - 1487.000 (Fig. 4, alt. 4)
1560.000 - 1567.000 (Fig. 4, alt. 4)
1580.000 - 1587.000 (Fig. 4, alt. 4)
1315.000 -
1586.000
(Fig. 4, alt. 4)
Models with electronic thermostat 400V.
Permanent installation. * (night economy)
*
1470.000 - 1477.000 (Fig. 4, alt. 1)
1490.000 - 1497.000 (Fig. 4, alt. 2)
1570.000 - 1577.000 (Fig. 4, alt. 2)
1590.000 - 1597.000 (Fig. 4, alt. 2)
Installation
1. Permanent fitting.
The wall frames supplied should be mounted using the screws provi-
ded. They should be about 100 - 150 mm in from each end of the radi-
ator. It is important that the radiator be mounted horizontally and that
the minimum dimensions shown in Figs. 1 and 2 are adhered to. The
radiator should not be installed directly beneath a power outlet or in
such a way that anyone using the baths, showers or pools could come
into contact with live equipment such as a switch.
1.1 Stand-alone installation.
Radiators with floor attachments may also be used free-standing. The
feet supplied should be attached by pressing them firmly onto the radi-
ator as in Fig 3.
1.2 Connections.
When the radiator is supplied with a junction box (Fig 4, Alt. 1), conn-
necting cable (Fig. 4 or 2), it should be connected by an authorised
electrician and all-pole switch should be installed. The junction box
can conveniently be placed over an existing mounting or conduit
behind the radiator. For details of attaching the radiator see Fig. 4,
depending on which model is being installed. Models 1470.000 -
1477.000 are set up for a 4 degree temperature interval under control
of a timer or similar. (Fig. 4, Alt. 1).
Important! The radiator must be connected to an earthed outlet of
the appropriate voltage.
Use
2. Setting temperature.
The radiator is switched on by setting the switch marked I and O in
position I. The desired temperature is set by turning the thermostat
clockwise to increase and anti-clockwise to decrease the setting. The
LED on electronic radiators only lights up when the radiator is wor-
king. When the desired temperature is set it is maintained automati-
cally. Thermostat temperature regulation range: 5–35ºC.
2.1 Calibrating the thermostat knob.
Calibrate the thermostat knob as follows.
(applies to models 1460.000 - 1467.000 and 1470.000 - 1477.000)
1. Remove the cover by turning the screw on the cover 90º
anti-clockwise (fig. 5 ex. 1).
2. Lift off the cover (fig. 5 ex. 2).
3. Release the thermostat knob by inserting a screwdriver into the
slot under the knob (fig. 5 ex. 3).
4. Lift off the knob (fig. 5 ex. 4).
5. Refit the knob so that it indicates the same temperature as a
thermometer placed in the room. Refit the cover.
2.2 Night economy.
Models 1460.000–1467.000/1470.000–1477.000 have a night econo-
my mode. When the 'Sun – Moon' switch is set to 'Moon' the tempera-
ture will be reduced by 4 degrees.
2.3 Overheating.
The radiator is prevented from overheating by a relay that switches off
the mains power when the radiator becomes too hot. It is reset by swit-
ching off the radiator for about 15 minutes, or by pressing the
brown/red switch behind the thermostat (applies to models 1460.000 -
1467.000 and 1470.000 - 1477.000).
Radiators for wall mounting
or stand-alone installation,
supplied with wall mounting frame
floor attachment, electric lead and plug,
Enclosure group IP 21.
Radiator for wall mounting,
supplied with wall mounting frame,
junction box (Alt. 1),
or electric cable (Alt. 2).
Enclosure group IP 21.
Models with bimetallic thermostat 230V.
Lead with earthed plug.
1380.000 - 1387.000 (Fig. 4, alt. 4)
1316.100
(Fig. 4, alt. 4)
1315.100
(Fig. 4, alt. 4)
1383.100
(Fig. 4, alt. 4)
Models with bimetallic thermostat 400V.
Permanent installation.
1390.000 - 1397.000 (Fig. 4, alt 2/3)
2.4 Maintenance.
For cleaning ensure that only non-abrasive cleaners are used.
Precautions
3. Remember:
• Do not cover' means that the radiator is not to be used for drying
clothes or textiles by placing them directly over its surface.
• This radiator is filled with the correct amount of special oil, so repairs
that involve the radiator being opened may only be carried out by the
manufacturer.
• Any leaks must be rectified by the manufacturer.
• The radiator must be installed with the thermostat at the
bottom edge, i.e. where the connecting cable comes out
otherwise there is a risk of overheating/fire.
• If the mains lead is damaged, return the radiator to the place of
purchase.
4. If you have problems...
• Ensure that the radiator is properly connected.
• Check the fuse.
• Check the overheating protection circuit described in section 2.3.
• If the radiator still fails to work, contact the manufacturer or supplier.
Guarantee
The current guarantee period is for 2 years. If you have any problems
or need repairs please contact the manufacturer or supplier.
Important! To simplify procedure always keep a copy of the
receipt of purchase and fill in the relevant details in the guarantee
certificate.

GUARANTEE CERTIFICATE

Two years' guarantee
is provided on this product by GNOSJÖ KLIMATPRODUKTER AB from the date it is
supplied to the purchaser. This guarantee covers faults arising from manufacture. It does
not include careless handling or breakdowns from connecting to the wrong supply vol-
tage. This certificate should be kept by the purchaser and returned together with the faul-
ty product - freight charges paid - to
Gnosjö Klimatprodukter AB
Box 162
SE-335 24 Gnosjö
Sweden
Article
....................................................................................................................................
Serial No.
.............................................................................................................................
Date of purchase
............................................................................................................
Supplier
................................................................................................................................
Reason for return
..........................................................................................................
This certificate is only valid when filled in correctly or if the purchase can be authenti-
cated in some other way. Otherwise any repairs carried out will be charged for.
IP 21
Radiator for wall mounting
or stand-alone installation,
supplied with wall mounting frame,
floor attachment, electric lead and plug.
Enclosure group IP 21.
Radiator for wall mounting,
supplied with wall mounting frame,
electric lead (Alt. 2).
Enclosure group IP 21.