Victron energy BlueSolar PWM DUO-LCD-USB Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
5. Alarms
6
High temperature
When temp ≥ 85℃, the
LCD-USB
will lower the PV input current in order to lower the
temp. There is no alarm on the LCD display.
When temp >90℃, the
USB
the PV input current will be reduced to zero, the high temp
alarm icon will show on the LCD. After the temp has decreased
to less than 82℃,
BlueSolar PWM DUO 12V|24V|20A LCD-USB
will resume normal operation.
Low battery1 voltage
Battery1 voltage <10.6V
Low battery2 voltage
Battery2 voltage <10.6V
High battery1 voltage
Battery1 voltage >16.5V
High battery2 voltage
Battery2 voltage >16.5V
High USB voltage
USB voltage >5.6V
BlueSolar PWM DUO 12V|24V|20A
BlueSolar PWM DUO 12V|24V|20A LCD-

Publicité

Table des Matières
loading

Table des Matières