Change settings in
Main display.
Press the MENU
button for several
seconds until the
display flashes, you are
in:
Battery type
LEAD-ACID
b01
[AGM]
LEAD-ACID
b02
[Gel]
LEAD-ACID
b03
[Wet]
b04
LiFePO4
b05
LiFePO4
Press on the MENU
key again and you
are in:
Note: In the normal charging status, the controller will divide the charging as the setting.
When battery #1 is fully charged, more charge current will go to battery #2.
When the controller detects that only battery #1 is connected, all the charge current will go
to the battery #1 automatically.
Press on the MENU
key again and you
are in:
4
Main display: battery1 voltage, battery state of charge, charging
status.
If arrow is flashing charger is in float.
By arrow of: no solar available.
Press MENU
Battery
Absorbtion
voltage
voltage
12.0V [24V]
14.4V [28.8V]
12.0V [24V]
14.2V [28.4V]
12.0V [24V]
14.6V [29.2V]
12.8V
14.2V
25.6V
28.4V
to enter next display.
Battery type setting.
See table below.
The factory setting is b01
Float voltage
13.7V [27.4V]
13.7V [27.4V]
13.7V [27.4V]
13.35V
26.7V
Charging Ratio of Battery 1
Current ratio to battery1
20% means 20% of available current
to battery 1 and 80% to Battery2
during Bulk phase.
The factory setting is 50%
Charging Frequency
Frequency switching between
Battery1 and Battery2: 25, 50 or
100Hz
The factory setting is 25Hz
Low voltage
Low voltage
disconnect
reconnect
11.2V [22.4V]
12.6V [25.2V]
11.2V [22.4V]
12.6V [25.2V]
11.2V [22.4V]
12.6V [25.2V]
11.2V
12.6V
22.4V
25.2V