Induktives Signalübertragungssystem
INDUS rail 71-242 + INDUS rail 71-942
Betriebsanleitung
(Original, Gültigkeit siehe letzte Seite)
INDUS rail 71-242 + INDUS rail 71-942 Sicherheitsschaltgerät
Operating Manual
INDUS rail 71-242 + INDUS rail 71-942 Safety Relay
Manuel d'utilisation
INDUS rail 71-242 + INDUS rail 71-942 Relais de sécurité
/
Inductive signal transmission system
(see last page for validity)
(Validité voir la dernière page)
/
Système de transmission de signal inductif
Seite 3-14
Page 15-26
Page 27-38

Publicité

Table des Matières
loading

Sommaire des Matières pour ASO Safety Solutions INDUS rail 71-242

  • Page 1 INDUS rail 71-242 + INDUS rail 71-942 Sicherheitsschaltgerät Seite 3-14 Operating Manual (see last page for validity) INDUS rail 71-242 + INDUS rail 71-942 Safety Relay Page 15-26 Manuel d’utilisation (Validité voir la dernière page) Page 27-38 INDUS rail 71-242 + INDUS rail 71-942 Relais de sécurité...
  • Page 2 Übergabedokumentation / Documentation / Documentation de datation / Documentazione di consegna / Documentatie Anlagenbeschreibung / Description / Description du système / Descrizione impianto / Beschrijving van de installatie Anlagenart / Type of plant / Sorte du système / Tipo d’impianto / Type installatie Hersteller / Manufacturer / Fabricant / Produttore / Fabrikant Seriennummer / Serial number / Numéro de série / Numero di serie / Seriennummer Datum der Inbetriebnahme / Commissioning date / Date de mise en marche / Data della messa in funzione...
  • Page 3: Table Des Matières

    INDUS rail 71-242 + INDUS rail 71-942 Induktives Signalübertragungssystem 1. Inhaltsverzeichnis 1. Inhaltsverzeichnis ......3 2.
  • Page 4: Allgemeine Sicherheitsbestimmungen Und Schutzmaßnahmen

    Induktives Signalübertragungssystem 2. Allgemeine Sicherheitsbestimmungen und Schutzmaßnahmen • Hersteller oder Benutzer der Anlage / Maschine, an der die Schutzeinrichtung verwendet wird, sind dafür verantwortlich, alle geltenden Sicherheitsvorschriften und -regeln in eigener Verantwortung abzustimmen und einzuhalten. • Die Schutzeinrichtung garantiert in Verbindung mit der übergeordneten Steuerung eine funktionale Sicherheit, nicht aber die Sicherheit der gesamten Anlage / Maschine.
  • Page 5: Allgemeines Und Funktionsbeschreibung

    Wenn eine Fehlermeldung vorliegt, sind alle Sicherheitsausgänge inaktiv. 4. Bestimmungsgemäße Verwendung Das Schaltgerät INDUS rail 71-242 (INDUS rail 71-942) kann seine sicherheitsrelevante Aufgabe nur erfüllen, wenn es bestimmungsgemäß eingesetzt wird. Das Sicherheitsübertragungssystem INDUS rail 71-242 (INDUS rail 71-942) ist ausgelegt für die Auswertung von feststehenden und mitfahrenden Sicherheitskontaktleisten mit konstantem 8,2KΩ...
  • Page 6: Systemkomponenten Am Tor

    Induktives Signalübertragungssystem 5. Systemkomponenten am Tor 10 1 2 3 11 Applikationsbeispiel 1 Steuergerät INDUS rail 71-242 (INDUS rail 71-942) 2 Feststehender Spulenkern Die Anordnung der einzelnen Komponenten ist 3 Mitfahrender Spulenkern abhängig von der jeweiligen Torkonstruktion und 4 Stahlseil als Übertragungsmedium von baulichen Gegebenheiten.
  • Page 7: Anschlussklemmen

    7.1 Voraussetzungen • Verlegung der Signalleitung darf nicht parallel zur Motorleitung oder anderen Leistungsleitungen erfolgen. • Die Versorgungsspannung der INDUS rail 71-242 und der INDUS rail 71-942 muss den Anforderungen für Schutzkleinspannung (SELV) entsprechen. • Leitungen, die im Freien oder außerhalb vom Schaltschrank verlegt werden, müssen entsprechend geschützt werden.
  • Page 8: Anschluss Steuerstromkreise

    Induktives Signalübertragungssystem 7.5 Anschluss Steuerstromkreise An das Klemmenpaar 4, 5 ist der zu überwachende Steuerstromkreis für die Auf-Bewegung (Stop-Auf-Bewegung) und an das Klemmenpaar 6, 7 der entsprechende Steuerstromkreis für die Zu-Bewegung (Stop- Zu-Bewegung) anzuschließen. Die Steuerstromkreise sind abhängig vom Nennstrom mit einer entsprechenden Sicherung zu schützen, oder der Nennstrom auf den Steuerstromkreisen muss durch andere Maßnahmen auf den maximalen Wert begrenzt werden.
  • Page 9: Fehlerdiagnose

    Liegt der Fehler nicht in der Verdrahtung, kann die Funktion der Elektronik durch Belegung aller Sicher- heitskontaktleisten-Eingänge an der INDUS rail 71-242 (INDUS rail 71-942) Auswertelektronik (Klemmen 3, 10 und Klemmen 3, 11) und am mitfahrenden Spulenkern (Anschlüsse O und C) mit jeweils einem 8,2 kΩ...
  • Page 10: Außerbetriebnahme Und Entsorgung

    Relais Stufen Nennstrom DC 30 V DC Nennstrom AC 30 V AC Mech. Lebensdauer >10 Betätigungen Schaltzeiten Sicherheitsrelais INDUS rail 71-242 Leiste Leiste feststehend mitfahrend Ausschaltverzögerung (Reaktionszeit) < 10 ms < 30 ms Einschaltverzögerung 500 ms (Power on 700 ms)
  • Page 11: Eg Konformitätserklärung

    INDUS rail 71-242 + INDUS rail 71-942 Induktives Signalübertragungssystem 13. EG Konformitätserklärung Hiermit erklären wir, dass die nachfolgend bezeichneten Produkte der Baureihe: INDUS rail 71-242 (Artikelnummer 1204-0100, Format Seriennummer yymmnnnnn) INDUS rail 71-942 (Artikelnummer 1204-0110, Format Seriennummer yymmnnnnn) Induktive Übertragungsvorrichtung mit Sicherheitsschaltsystem zur Kombination mit...
  • Page 13 INDUS rail 71-242 + INDUS rail 71-942 Inductive signal transmission system 1. Contents 1. Contents ......13 2.
  • Page 14: General Safety Regulations And Protective Measures

    Inductive signal transmission system 2. General safety regulations and protective measures • The manufacturer and users of the plant / machine on which the protection is being used are responsible for implementing and following all applicable safety regulations and rules. •...
  • Page 15: General And Function

    If an error is present, all the safety outputs are not active. 4. Proper use The INDUS rail 71-242 (INDUS rail 71-942) switching unit can only fulfil its safety-related task if used properly. The INDUS rail 71-242 (INDUS rail 71-942) safety transmission system is designed for evaluating stationary and travelling safety contact edges with constant 8.2 kΩ...
  • Page 16: System Components Fitted To The Gate

    Inductive signal transmission system 5. System components fitted to the gate 10 1 2 3 11 Example of use 1 INDUS rail 71-242 (INDUS rail 71-942) control device 2 Stationary coil core The actual arrangement of the individual components 3 Travelling coil core depends on the design of the gate in question and the conditions at the installation site.
  • Page 17: Connection Terminals

    • The signal cable must not be placed parallel to the motor cable or other power cables. • The supply voltage used for the INDUS rail 71-242 and the INDUS rail 71-942 must comply with the requirements for safety low voltage (SELV).
  • Page 18: Connecting The Control Circuits

    Inductive signal transmission system 7.5 Connecting the control circuits The control circuit to be monitored for the opening movement (stop- opening movement) is to be connected to terminal pair 4, 5 ; for the closing movement (stop-closing movement), the appropriate control circuit is to be connected to terminal pair 6, 7.
  • Page 19: Error Diagnosis

    If the error is not in the wiring, the function of the electronics can be tested by connecting an 8.2 kΩ resistor to all safety contact edge inputs on the INDUS rail 71-242 (INDUS rai 71-942) electronic evaluation system (terminals 3, 10 and terminals 3, 11) and to the travelling coil core (connections O and C).
  • Page 20: Taking Out Of Service And Disposal

    Relay stages Nominal current DC 30 V DC Nominal current AC 30 V AC Mech. life-time >10 actuations INDUS rail 71-242 Safety relay switching times Stationary Travelling contact edge contact edge Switching off delay (response time) < 10 ms < 30 ms...
  • Page 21: Ec Declaration Of Conformity

    INDUS rail 71-242 + INDUS rail 71-942 Inductive signal transmission system 13. EC declaration of conformity We hereby declare that the following product: INDUS rail 71-242 (part no. 1204-0100, serial number format yymmnnnnn) INDUS rail 71-942 (part no. 1204-0110, serial number format yymmnnnnn)
  • Page 23 INDUS rail 71-242 + INDUS rail 71-942 Système de transmission de signal inductif 1. Table des matières 1. Table des matières ......23 2.
  • Page 24: Prescriptions Générales De Sécurité Et Mesures De Protection

    Système de transmission de signal inductif 2. Prescriptions générales de sécurité et mesures de protection • Le fabricant et l'utilisateur du système / de la machine sur lequel est placé le dispositif deprotection, ont la responsabilité d'appliquer et de suivre toutes les directives et règles de sécurité en vigueur. •...
  • Page 25: Généralités Et Fonctionnement

    Si une erreur est présente, toutes les sorties de sécurité sont désactivées. 4. Utilisation conforme Le relais de sécurité INDUS rail 71-242 (INDUS rail 71-942) ne peut remplir ses fonctions de sécurité que s‘il est utilisé de façon conforme. Le système de transmission de sécurité INDUS rail 71-242 (INDUS rail 71-942) est conçu pour l'évaluation de barres palpeuses stationnaires et mobiles avec une résistance constante de 8,2 kΩ.
  • Page 26: Composants Du Système Sur Le Portail

    5. Composants du système sur le portail 10 1 2 3 11 Exemple d'application 1 Appareil de commande INDUS rail 71-242 (INDUS rail 71-942) La disposition des différents composants dépend 2 Noyau de bobine fixe de la construction spécifique du portail et des 3 Noyau de bobine mobile caractéristiques des bâtiments.
  • Page 27: Système De Transmission De Signal Inductif

    • La pose des câbles de signal ne doit pas se faire en parallèle du câblage de la commande ou d’autres câblages. • L'alimentation de l'INDUS rail 71-242 et de l'INDUS rail 71-942 doit répondre aux exigences de la très basse tension de protection (TBTP).
  • Page 28: Raccordement Des Circuits De Contrôle

    Système de transmission de signal inductif 7.5 Raccordement des circuits de contrôle Raccordez le circuit de contrôle à surveiller pour le mouvement d'ouverture (arrêt d'ouverture) aux bornes marquées 4, 5 et le circuit de contrôle de fermeture correspondant (arrêt de fermeture) aux bornes marquées 6, 7.
  • Page 29: Diagnostic D'erreurs

    INDUS rail 71-242 + INDUS rail 71-942 Système de transmission de signal inductif 10. Diagnostic d'erreurs Si le câblage est correct, lors de la mise sous tension, seule la LED verte doit briller. Si une des LED rouges s'allume, il y a une erreur dans le système que la LED allumée permet de localiser.
  • Page 30: Mise Hors-Service Et Élimination

    30 V CC Courant nominal CA 30 V CA Durée de vie mécanique >10 actionnements Temps de commutation du relais de sécurité INDUS rail 71-242 barre palp. barre palp. fixe mobile Retard au déclenchement (temps de réaction) < 10 ms <...
  • Page 31: Déclaration De Conformité Ce

    INDUS rail 71-242 + INDUS rail 71-942 Système de transmission de signal inductif 13. Déclaration de conformité CE Nous déclarons par la présente que le produit: INDUS rail 71-242 (article n° 1204-0100, format de numéro de série yymmnnnnn) INDUS rail 71-942 (article n°...
  • Page 32 Induktives Signalübertragungssystem Inductive signal transmission system Système de transmission de signal inductif 12.DB.04.111 Betriebsanleitung Rev 06 Deutsch Technische Änderungen vorbehalten. Für Irrtümer und Druckfehler kann keine Haftung übernommen werden. Diese Betriebsanleitung ist für folgende Versionsstände gültig: von V 1.0 bis V 4.0 12.DB.04.111 Operating Manual Rev 06 English Subject to technical modifications.

Ce manuel est également adapté pour:

Indus rail 71-942

Table des Matières