AquaKinetic Softener Owners Manual
.

Operating Parameters and Specifications

Installation of this product must comply with local plumbing laws
Provisions for an antisiphon air gap should be part of the installation to
prevent a cross connection between the water system and the waste
system
Waste connections or drain outlets shall be designed and constructed to
provide for connection to the sanitary water system through an air gap
of 2 pipe diameters or 1 inch (25mm) whichever is larger.
Do not use on water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system, or that
contains high concentrations of sediment, dirt or other suspended
matter without additional treatment steps.
It is recommended that before purchasing a water treatment unit, you
have your water supply tested to determine your actual water treatment
needs.
Kinetico recommends the use of a high quality grade pure salt (sodium
chloride) processed especially for water conditioners.
Water conditioners using sodium chloride for regeneration add sodium
to the water. Individuals who are on sodium restricted diets should
consider the added sodium as part of their overall sodium intake.
Minimum Operating Pressure:
Maximum Operating Pressure:
Maximum Working Pressure:
Minimum Operating Temperature:
Maximum Operating Temperature:
Model
Flow Rate
15 psi
Q237
8 gpm
Rev. 10/2010
Flow Rate
Resin per
30 psi
Tank
12 gpm
.30 ft3
Page 10
15 psi (103.4 kPa)
125 psi (861.9 kPa)
125 psi (861.9 kPa)
o
o
35
F (2
C)
o
o
120
F (49
C)
Capacity
(lb setting)
4014 (1)
4366 (1.25)
Grains per
Pound
4014
3493
Product No. 13146B