Preparation

Parts provided:
• Anti-Tip Bracket
• 2 wood screws
• 2 anchorless concrete screws
tools and parts needed:
• Range Power Supply Cord Kit with strain relief
(240V - 30 Amps)*
• Standard Measuring Tape
• Phillips Head Screwdriver
• 1-1/4" Wrench
• Pencil
• T-20 Torx Screwdriver
• 3/8" Nut Driver
• Pipe Wrench (2)
• Teflon® Tape** or Pipe Joint Compound
(Appropriate for use with LP gas and Natural gas)
• Channel Lock Pliers
• Gas Leak Test Solution
• Level
• Drill and Drill Bit (3/16" masonry bit for
concrete screws)
• Gas Supply Line (Flexible Metal Appliance
Connector or Rigid Pipe)
• Gas Shut Off Valve (If not already present)
• Gloves and Safety Goggles
* Not needed for Canadian installations
** Teflon is a registered trademark of DuPont
1. Install ventilation
Bosch strongly recommends the installation of a
ventilation hood above this range. For most kitchens
a certified hood rating of not less than 300 CFM is
recommended. The range hood must be installed ac-
cording to instructions furnished with the hood.
note: The appliance should not be installed with a
ventilation system that blows air downward toward
the burners. This type of ventilation system may
cause ignition and combustion problems with the
gas cooking appliance resulting in personal injury or
unintended operation.
2. Prepare cabinets
This unit is designed for installation near adjacent
walls and projected surfaces constructed of combus-
tible materials.
Allow a minimum of 30"(76.2 cm) between cabinets
where range is to be installed**.
30in (76.2 cm )
min. centered
30in (76.2 cm) min.
4in (10.2 cm )
min
no clearance required (12 mm clearance from
range sidewall to cabinet required in Canada.)
required clearances*
From cooktop to materials above
There must be a minimum clearance of 30" (76.2 cm)
between the top of the cooking surface and the bot-
tom of an unprotected wood or metal cabinet.
24" (60.7 cm) is acceptable when the bottom of the
wood or metal cabinet is protected by (a) not less
than 1/4" (6.4 mm) of flame retardant material which
must be covered with (b) not less than No. 28 MSG
sheet metal, 0.015" (0.4 mm) stainless steel or
0.024" (0.6 mm) aluminum or copper.
From range walls to adjacent materials
No clearance is required from unit walls to adjacent
vertical combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls
must be at least 4" (10.2 cm).
note: Some cabinet finishes cannot survive the tem-
peratures allowed by U.L., particularly self-cleaning
ovens; the cabinets may discolor or stain. This is
most noticeable with laminated cabinets.
4in (10.2 cm)
min